Telemecanique 9012GKW5 2-Stage Electromechanical Pressure Switch, 3 to 150 psi Pressure, 12 psi Differential, 2NC-2NO Contact, NPT Conduit/Screw Clamp Connection, 10 A at 480 VAC Contact
Pressure Control Switches
100393
MFG #: 9012GKW5
Telemecanique Sensors
608.21000
/ ea
- Brochure URL - fdb8c2d44e5c6f5f2e6b224c7d6fe279a0405b17.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADID0005278_2D-left.dwg(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - goto?PartNumber=9012GKW5(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_R54TJHN6O203XS1M.pdf(Install Instructions 1 URL)
- Install Instructions 1 URL - files?p_File_Name=65013-009-31_01.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_CN8RVX013QY6IDJE.pdf(Service Manual URL)
- Service Manual URL - 11003_CPJTB8F0X1VINW4H.pdf(Service Manual URL)
- Service Manual URL - files?p_enDocType=End of life manual&p_File_Name=ENVEOLI111210EN_V0.pdf(Service Manual URL)
- Spec Sheet URL(Spec Sheet URL)
- Spec Sheet URL - 11003_M51ISBH7UDNPYVA4.pdf(Spec Sheet URL)
- Applications
- Features
Compressed Air Systems, HVAC Equipment, Chillers, Pumping Systems, Machine Tools, Stamping Presses, Automatic Grinders, Welders, Process Equipment, Molding Machines, Indoor/Outdoor and General Purpose Applications and Regulation Between 2 Thresholds |
SCREW-CLAMP TERMINALS, AWG 22...AWG 12 |
High shock-resistance |
High set-point stability |
Internal or external range adjustment |
No drain line required |
Dual numerical range scale (psi and kPa) |
Diaphragms of FKM fluorocarbon or ethylene propylene are available as well as stainless steel flanges |
2NC 2NO, 2 SPDT-DB, form Z, snap action, silver nickel contacts |
-40 to 250 deg F hydraulic oil, air, non-corrosive liquid and non-corrosive gas |
1/4 in 18 NPTF conforming to UL 508 fluid connection |
8 screw terminal blocks |
8 screw terminal blocks |
22 to 12 AWG electrical connection |
Zinc plated steel flange |
Nitrile (Buna-N) diaphragm |
8 psi stage 1 +/- 2 psig +/- 2.5% full scale approx. differential at mid range 12 psi stage 2 +/- 3 psig |
1/2 in NPT conduit entrance cable entry |
Die cast aluminum alloy housing |
Panel mounting |
150 psi system pressure |
Corrosion-resistant |