SmartlockPro® GFNT2-FW Duplex Outlet Self-Test GFCI Receptacle With LED Indicator, 125 VAC, 20 A, 2 Poles, 3 Wires, White
Receptacles and GFCI
932028
MFG #: GFNT2-FW
Leviton®
25.37000
/ ea
Peace of mind, all the time. The SmartlockPro self-test GFCI tests itself even if you forget. Designed to meet the latest UL standard for auto-monitoring (self-test) our complete line of self-test GFCIs periodically conduct an automatic internal test to confirm that it can respond to a ground fault. With the slimmest profile on the market, the device allows for fast and easy installation, while Leviton's patented reset lockout mechanism prevents reset of the GFCI if it is not wired or operating correctly. The SmartlockPro self-test GFCI is the smart choice in ground fault circuit interrupter protection.
- http://www.leviton.com(Seller Home Page URL)
- Install Instructions URL - SmartlockPro_GFNT2_Installation_Sheet.pdf(Install Instructions URL)
- Safety Data Sheet URL - MSDS.pdf(Safety Data Sheet URL)
- Spec Sheet 1 URL - ID-SPE-v1-GFNT2-FW.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 10962_ID-SPE-v1-GFNT2-FW.pdf(Spec Sheet URL)
- Tech Bulletin URL - SmartlockPro_GFNT1_GY_Technical_Bulletin.pdf(Tech Bulletin URL)
- Tech Drawing URL - SmartlockPro_GFNT1_E_Installation_Sheet.pdf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/T-1fWxB5WtA(Video)
- Applications
- Features
Residential/Commercial |
NAFTA Compliant |
Provides continuous ground fault protection - detects and trips on actual ground fault even when self-test is being conducted |
On initial power up, tests the GFCI within 3 seconds |
Auto-monitoring exceeds the UL requirement |
Auto adapts and shifts to more frequent testing if potential problem is detected |
Testing frequency regularly updates protection status |
Electronics are designed to minimize any false triggers |
Patented bridge contact provides individual sets of contacts for GFCI receptacle face and downstream receptacles; no power will be delivered to receptacle face if improperly wired (line-load reversed) |
Trip threshold meets or exceeds UL requirements for tripping time |
Improved immunity to high frequency noise reduces nuisance tripping |
Advanced electronics design provides superior resistance to electrical surges and over-voltages |
Patented lockout action prevents reset if GFCI is damaged and cannot respond to a ground fault |
Status indicator light provides simple, intuitive feedback on power and protection status as well as indication of line/load reversal |
Silver alloy contacts |
20 A feed-through current and impact-resistant thermoplastic cover and body |
One-piece T-design trip latch mechanism provides efficient operation |
Compatible with all Decora devices and wallplates |
Withstands 2000 VAC per UL498 |
10 kA short circuit current rating |
Maximum 30 deg C after 100 cycles OL at 150% rated current temperature rise |
Rated V-2 per UL94 flammability |