Schneider Electric TeSys™ K LC2K Reversing IEC Contactor LC2K0601F7, 110 VAC Coil, 0.25 Max Load, 3NO, 3 Poles
Contactors
35044
MFG #: LC2K0601F7
Schneider Electric
140.62000
/ ea
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=8074859360Den&ext=webp(360 Degree View URL)
- Brochure URL - 115967977b38aa63fd29e8e8024eb8003e40dffe.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=E0210301-01.DWF(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=E0210301-01.dwg(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_2HQM3AP08GO6W9RD.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_3V7HC94PLOQNRATG.pdf(Service Manual URL)
- Service Manual URL - 11003_ZS45DFC0LRUIV97B.pdf(Service Manual URL)
- Spec Sheet 1 URL - Schneider_Electric_LC2K0601F7_Datasheet.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 11003_DSB43I8F1A6CRX0K.pdf(Spec Sheet URL)
- Tech Drawing URL - 11003_V8FOL0TE4AY6ZJ7B.zip(Tech Drawing URL)
- Tech Drawing URL - files?p_enDocType=Technical+Drawing&p_File_Name=E0210301-01.dwg(Tech Drawing URL)
- Video - https://www.youtube.com/embed/e8UrRZljFg0(Video)
- Applications
- Features
Motor control |
20 A AT <= 50 °C FOR POWER CIRCUIT-10 A AT <= 50 °C FOR SIGNALLING CIRCUIT,MECHANICAL |
8 kV rated impulse withstand voltage |
III overvoltage category |
20 A at <=122 deg F (50 deg C) power circuit/10 A at <=122 deg F (50 deg C) signaling circuit conventional free air thermal current |
25 A gG at <=440 V power circuit/25 A aM power circuit/10 A gG signaling circuit conforming to IEC 60947/10 A gG signaling circuit conforming to VDE 0660 associated fuse rating |
3 mOhm at 50 Hz - Ith 20 A power circuit average impedance |
Mechanical interlock |
1.3 Nm on screw clamp terminals with screwdriver Philips No 2/flat 6 mm diameter tightening torque |
10 to 20 ms coil de-energisation and NO opening/coil energisation and NO closing operating time |
3600 cycles/hr operating rate |
30 VA at 68 deg F (20 deg C) inrush power |
4.5 VA at 68 deg F (20 deg C) hold-in power consumption |
1.3 W heat dissipation |
<=400 Hz signaling circuit frequency |
5 mA signaling circuit minimum switching current |
17 V signaling circuit minimum switching voltage |
0.02 in (0.5 mm) non-overlap distance |
>10 MOhm signaling circuit insulation resistance |
TC protective treatment |
6561.68 ft (2000 m) without derating in temperature operating altitude |
3 kW at 440 VAC 50/60 Hz, 3 kW at 500 to 600 VAC 50/60 Hz, 3 kW at 660 to 690 VAC 50/60 Hz, 1.5 kW at 220 to 230 VAC 50/60 Hz |