Schneider Electric TeSys™ D LC2D Reversing IEC Contactor With Protective Cover, 120 VAC Coil, 80 A Max Load, 3NO, 3 Poles
Contactors
98453
MFG #: LC2D80G7
Schneider Electric
1100.51000
/ ea
- Brochure URL - 11003_9PT1LU7VOI5CXNW3.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=LC2D80G7_2D-back.dwg(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADPD0004129_2D-left.dxf(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - files?p_File_Name=W9 0444935 0114 12.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Spec Sheet 1 URL - Schneider_Electric_LC2D80G7_Datasheet.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 11003_9F74E1GVHA2L5W68.pdf(Spec Sheet URL)
- Tech Drawing URL - 11003_L298O734IGTHQVX6.dwg(Tech Drawing URL)
- Tech Drawing URL - 11003_MQRXOFKEJ3L8GAHP.dwg(Tech Drawing URL)
- Video - https://www.youtube.com/embed/kW01lFljKgE(Video)
- Applications
- Features
Resistive load;motor control |
20 HP 200/208 V AC 60 HZ 3 PHASE-7.5 HP 115 V AC 60 HZ 1 PHASE-15 HP 230/240 V AC 60 HZ 1 PHASE-25 HP 230/240 V AC 60 HZ 3 PHASE-60 HP 460/480 V AC 60 HZ 3 PHASE-60 HP 575/600 V AC 60 HZ 3 PHASE,WITHOUT BUILT-IN SUPPRESSOR MODULE |
Pre-assembled with reversing power busbar |
6 kV conforming to IEC 60947 rated impulse withstand voltage |
III overvoltage category |
125 A at 140 deg F power circuit, 10 A at 140 deg F signaling circuit conventional-free air thermal current |
1100 A at 440 V power circuit conforming to IEC 60947/140 A AC signaling circuit conforming to IEC 60947-5-1/250 A DC signaling circuit conforming to IEC 60947-5-1 IRMs rated making capacity |
1100 A at 440 V power circuit conforming to IEC 60947 rated breaking capacity |
160 A gG at 690 V coordination type 2-power circuit, 200 A gG at 690 V coordination type 1 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1 associated fuse rating |
At 50 Hz - Ith 60 A for power circuit average impedance |
Mechanical interlock |
6 to 20 ms opening/20 to 35 ms closing operating time |
3600 cycles/hr at <=140 deg F (60 deg C) operating rate |
Without built-in suppressor module coil technology |
245 VA at 68 deg F (20 deg C) 50/60 Hz inrush power |
26 VA at 68 deg F (20 deg C) 60 Hz/26 VA at 68 deg F (20 deg C) 50 Hz hold-in power consumption |
6 to 10 W heat dissipation |
25 to 400 Hz signaling circuit frequency |
5 mA signaling circuit minimum switching current |
17 V signaling circuit minimum switching voltage, TH protective treatment |
1.5 ms on de-energisation (between NC and NO contacts)/1.5 ms on energisation (between NC and NO contacts) non-overlap time, >10 MOhm signaling circuit insulation resistance |
-40 to 158 deg F permissible ambient air temperature around the device, -76 to 176 deg F storage temperature |