Schneider Electric TeSys™ D LC1D IEC Contactor With Protective Cover, 24 VDC Coil, 50 A Max Load, 3NO, 3 Poles
Contactors
61617
MFG #: LC1D50BD
Schneider Electric
437.01000
/ ea
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=17182745360Den&ext=webp(360 Degree View URL)
- Brochure URL - 11003_9PT1LU7VOI5CXNW3.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=LC1D50BD_2D.dwf(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=LC1D50BD_2D.dxf(Computer~Aided [CAD|BIM] Model URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_WEJC1ZNTS3GF5P0H.pdf(Service Manual URL)
- Spec Sheet 1 URL - Schneider_Electric_LC1D50BD_Datasheet.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 11003_Z24XQAUJM5O3T091.pdf(Spec Sheet URL)
- Tech Bulletin URL - 11003_8G547S3DJIOHPNLZ.pdf(Tech Bulletin URL)
- Tech Bulletin URL - 11003_R8DPHVO6FAXJE9S2.pdf(Tech Bulletin URL)
- Video - https://www.youtube.com/embed/vlEODblcQoo&list=PLa7UGrWOTyjnMSGFb16ULXxkQpETEayVn(Video)
- Applications
- Features
Motor control;resistive load |
Built-in bidirectional peak limiting diode suppressor |
8 kV conforming to IEC 60947 rated impulse withstand voltage |
III overvoltage category |
80 A at <=140 deg F (60 deg C) power circuit/10 A at <=140 deg F (60 deg C) signaling circuit conventional free air thermal current |
250 A DC control circuit conforming to IEC 60947-5-1/900 A at 440 V power circuit conforming to IEC 60947 irms rated making capacity |
900 A at 440 VAC power circuit conforming to IEC 60947 rated breaking capacity |
10 A gG control circuit conforming to IEC 60947-5-1/100 A gG at <=690 V coordination type 1 power circuit/100 A gG at <=690 V coordination type 2 power circuit associated fuse rating |
20 ms opening/50 ms closing operating time |
3600 cycles/hr at <=140 deg F (60 deg C) operating rate |
Built-in bidirectional peak limiting diode suppressor coil technology |
19 W at 68 deg F (20 deg C) inrush power |
7.4 W at 68 deg F (20 deg C) hold-in power consumption |
34 ms time constant |
25 to 400 Hz signaling circuit frequency |
5 mA signaling circuit minimum switching current |
17 V signaling circuit minimum switching voltage |
1.5 ms on energisation between NC and NO contacts/1.5 ms on de-energisation between NC and NO contacts non-overlap time |
>10 MOhm signaling circuit insulation resistance |
TH protective treatment |
3 pollution degree |
-40 to 158 deg F permissible ambient air temperature around the device, -76 to 176 deg F storage temperature |