Schneider Electric METSEION92030, 90 to 480 VAC, 50 to 60 Hz
Power Meters
PDW~13599103
MFG #: METSEION92030
Square D™
0.00000
/ ea
- Brochure URL - 11003_2LYGJD4M5SH7196W.pdf(Brochure URL)
- Brochure URL - 11003_O6LCYXWQFUA1G2VP.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_ILHCJ84E71NG6POX.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_CB0JVKFSNWRL51A8.pdf(Service Manual URL)
- Spec Sheet URL - 11003_IRCSKO29381QAP6X.pdf(Spec Sheet URL)
- User Manual URL - 11003_U1I7SJHDTCB20QG9.pdf(User Manual URL)
- User Manual URL - 11003_W6HJM9UYIT527RSZ.pdf(User Manual URL)
- Applications
- Features
For both supply and demand side applications |
Restore power efficiently while keeping people safe and processes operational |
Ensure safe power recovery while switching utility feeds |
Avoid downtime by understanding root causes of acute or chronic power events, and prevent future occurrences |
Increase lifetime of equipment, mitigating effects of poor power quality |
Save money by reducing energy spend. Use actionable data to optimize operations, avoid peak demand or power factor penalties or errors in utility bills |
Demand current I1, I2, I3, I4, I5Peak demand currentsDemand power P, Q, SPeak demand power PM, QM, SMCalculated active and reactive energy (+/- W.h, +/- VAR.h) metering type |
EN 50160 compliance checkingIEEE 519 harmonic limitIEC 61000-4-30 class A compliance reportingIEEE 519 compliance reporting waveform capture total demand distortion total harmonic distortion up to the 63rd harmonic up to the 127th harmonic with software disturbance direction detection dip, swell and transient half cycle data acquisition transient detection (20 s) power quality analysis |
Voltage sags and swellsCurrent sags and swellsVoltageCurrentFrequencyActive and reactive power totalApparent power totalActive and reactive power per phaseApparent power per phasePower factor totalPower factor per phaseActive and reactive energyApparent energyHarmonic distorsion (I THD & U THD) type of measurement |
100 ms 6 cycles at 60 Hz 120 V AC typical400 ms 24 cycles at 60 Hz 240 V AC typical1200 ms 72 cycles at 60 Hz 480 V AC typical ride-through time |
1024 samples/cycle sampling rate |
1024 samples/cycle sampling rate |
01 to 20 A measurement current |
Voltage (impedance 5 MOhm)5 external CT 0.3 mOhm) input type |
57 to 400 V AC 42 to 69 Hz between phase and neutral100 to 690 V AC 42 to 69 Hz between phases measurement voltage |
20 to 450 Hz frequency measurement range |
8 digital 30 V AC/60 V DC number of inputs |
Voltage +/- 0.1 %Current +/- 0.1 % measurement accuracy |
4 digital2 form C relay number of outputs |
Modbus RTU 2400 to 115200 bps - 2-wireION 2400 to 115200 bps - 2-wireDNP3 2400 to 115200 bps - 2-wireModbus TCP 10/100 Mbit/sION TCP 10/100 Mbit/sDNP3 TCP 10/100 Mbit/sIEC 61850Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/sDHCPDNSDLMS communication port protocol |
2 RS485 removable screw terminal block communication port support |