GE LC1F115 LB1AC AC Coil, 24 VAC, 60 Hz, For Use With CL00, CL01, CL02, CL25 Contactor
Contactors
379423
MFG #: LC1F115
Schneider Electric
488.62000
/ ea
- Brochure URL - 11003_KSGYFRZ9O1J6MP3N.pdf(Brochure URL)
- Brochure URL - files?p_enDocType=Brochure&p_File_Name=TeSys_F1000_Brochure_US_033117.pdf(Brochure URL)
- Catalog URL - Schneider_Electric_LC1F500_Catalog.pdf(Catalog URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=LC1F115F.dwg(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_WPRQF1HY3JVAKSU6.pdf(Install Instructions 1 URL)
- Install Instructions 1 URL - files?p_File_Name=135581701A50-21.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_DJVCSG76MPK5WL98.pdf(Service Manual URL)
- Service Manual URL - 11003_UGSAYIR6HJKZQC5B.pdf(Service Manual URL)
- Service Manual URL - files?p_enDocType=End of life manual&p_File_Name=ENVEOLI111214EN_V1.pdf(Service Manual URL)
- Spec Sheet 1 URL - Schneider_Electric_LC1F115_Datasheet.pdf(Spec Sheet 1 URL)
- Tech Drawing URL - 4cd0ed740397befbf98a9a917f08eed4769415d1(Tech Drawing URL)
- Tech Bulletin URL - cf57f551292bfed3bee2fd92787f7a3f0929f473.pdf(Tech Bulletin URL)
- Tech Bulletin URL - 11003_8G547S3DJIOHPNLZ.pdf(Tech Bulletin URL)
- Tech Bulletin URL - 11003_R8DPHVO6FAXJE9S2.pdf(Tech Bulletin URL)
- Video - https://www.youtube.com/embed/e8UrRZljFg0(Video)
- Spec Sheet URL - 11003_SG632UCEIHBX0QD7.pdf(Spec Sheet URL)
- Tech Drawing URL - 11003_OXMH4KDSB8I3Z9YC.dxf(Tech Drawing URL)
- Spec Sheet URL - 72dec25426ef4bc0ec47da3d4d6f771d2cd1ef39.pdf(Spec Sheet URL)
- Spec Sheet URL - 11003_I2C8L91EJRGZ6SMT.pdf(Spec Sheet URL)
- Tech Drawing URL - files?p_enDocType=Technical+Drawing&p_File_Name=LC1F115F.dxf(Tech Drawing URL)
- Applications
- Features
Resistive load;motor control |
CONTACTOR ONLY (NO COIL) |
8 kV rated impulse withstand voltage |
III overvoltage category |
200 A at 104 deg F conventional free air thermal current |
920 A conforming to IEC 60947-4-1 rated breaking capacity |
125 A aM at 440 V/200 A gG at 440 V associated fuse rating |
0.37 MOhm at 50 Hz to Ith 200 A average impedance |
1000 V conforming to IEC 60947-4-1/1500 V conforming to VDE 0110 group C rated insulation voltage |
88.5 in-lb tightening torque power circuit |
23 to 35 ms closing/5 to 15 ms opening operating time |
2400 cycles/hr at 131 deg F operating rate |
660 VA at 68 deg F 60 Hz inrush power |
55 VA at 68 deg F 60 Hz hold-in power consumption |
12 to 16 W heat dissipation |
TH protective treatment |
-40 to 158 deg F permissible ambient air temperature around the device |
9842.52 ft without derating in temperature operating altitude |
Vibrations contactor closed 6 gn, 5 to 300 Hz/shocks contactor open 9 gn for 11 ms/vibrations contactor open 2 gn, 5 to 300 Hz/shocks contactor closed 15 gn for 11 ms mechanical robustness |
55 kW at 380 to 400 VAC 50/60 Hz AC-3, 59 kW at 415 VAC 50/60 Hz AC-3, 59 kW at 440 VAC 50/60 Hz AC-3, 75 kW at 500 VAC 50/60 Hz AC-3 motor power dissipation per pole |
30 kW at 220 to 230 VAC 50/60 Hz AC-3, 65 kW at 1000 VAC 50/60 Hz AC-3, 18.5 kW at 400 VAC 50/60 Hz AC-4, 80 kW at 660 to 690 VAC 50/60 Hz AC 3-ph motor power |
15 W (AC-1), 5 W (AC-3) power dissipation per pole |