• Features
Control system monitors a variety of input devices such as e-stop buttons, rope pulls, enabling device, protective safety stops, interlocked guards or gates, optical sensors, two-hand controls, and safety mats
Pre-configured safety function blocks including two-hand control, muting, enabling device, and more to simplify application programming
Boolean logic functions for programming flexibility
Intuitive programming environment for easy implementation
Expandable models for adding up to 8 additional i/o modules for larger scale applications
Base controller has 2 pairs of safety outputs and 26 safety inputs of which 8 may be configured as non-safety status output
Ethernet models available providing up to 64 virtual status outputs on fid 1 base controllers and up to 256 virtual status outputs on fid 2 base controller
Optional onboard LCD display for system status and diagnostic information
26 number of i/o points
2 pair number of safe outputs
OSSD 0.5 a maximum at 24 VDC safe output type
Screw terminal type
8 non safe outputs
110 in height, 45 in width and 129 in depth
0.14 A (controller only)/3.6 A (bus load) power consumption
Type 4, Category 4, Ple, SIL3, SIL CL3 design rating