Power blocks offer the ultimate in simplicity of sensor hookup; They wire directly in series with an ac load, exactly like a limit switch; Response time of 2-wire power blocks is determined by the scanner block, which is 10 MS on/off; A built-in false pulse protection circuit holds the output off for 100 MS after power is initially applied to the power block; 2-wire power blocks will operate from -40 to 70 ° C; Resistive loads must be less than 15000 OHM and inductive loads must be greater than 1.2 WTT; Output: SPST solid-state switch; Wiring chamber |
50/60 Hz input |
3/4 A maximum (derated to 1/2 A at 70 deg C) output |
10 A for 1 sec non-repeating maximum inrush |
Less than 10 V on-state voltage drop |
Less than 1 mA (resistive or inductive loads) leakage current |
Resistive loads must be less than 15000 Ohm and inductive loads must be greater than 1.2 W (10 mA) |
Range depends on sensor |
Wiring chamber |
2 m length cable connection |