• Features
0
Polycarbonate primary housing
20 to 50 mA at 12 to 30 VDC safety input - dual channel (dry contact), 20 to 50 mA at 12 to 30 VDC (dry contact only) safety input - reset
Category 4 PLe; SIL 3 design rating
1000000 cycles at 450 VA electrical life
90% at 50 deg C relative humidity
Simultaneous or concurrent input operation
4 NO (6 A); 1 NC (5 A) output configuration, 2 PNP
50000000 operations mechanical life
25 ms response time
Transient voltage/reverse polarity supply protection
115 VAC +/-15% (A1-A2); 11 - 27.6 VDC (B1-B2) supply voltage
10 to 55 Hz at 0.35 mm vibration; 60 to 150 Hz at 5 g maximum
AgNi 5 um gold-plated contacts
2 pollution degree
350 ms recovery time
Monitors emergency stop devices, such as palm buttons and rope/cable pulls, and positive-opening safety switches used for guard/gate interlocking
Four normally open output switching channels for connection to control-reliable power interrupt circuits and three auxiliary output channels
Automatic reset or monitored manual reset
For use in function stop category 0 application per ANSI NFPA 79 and IEC/EN60204-1
6 A safety output contacts; 5 A auxiliary output contacts