Schneider Electric METSEION92030, 90 to 480 VAC, 50 to 60 Hz

Power Meters
PDW~13599103 MFG #: METSEION92030
Square D™
19831.40000 / ea
  • Alternate Catalog Number: METSEION92030
  • Application: For both supply and demand side applications
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: METSEION92030
  • Country of Origin: CA
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 1852.80
  • Gross Volume per Pack Metric: 30361.83
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 5.5000 lb
  • Gross Weight per Pack Metric: 2.50
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 9028300000
  • Height: 11.70 in
  • Height [Metric]: 30.0000 cm
  • Length: 15.99 in
  • Length [Metric]: 41.0000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=468434884&lang=en-us
  • Returnable: Y
  • Substitute Product Catalog Number: PSA101115
  • UNSPSC: 83101808
  • Width: 11.70 in
  • Width [Metric]: 30.0000 cm
  • Brand: Square D™
  • Manufacturer: Schneider Electric
Schneider Electric METSEION92030, 90 to 480 VAC, 50 to 60 Hz Frequency, 0.1S, 0.5S, 0.1 Accuracy, 6.30 in H x 6.30 in W x 5.33 in D Dimensions
QTY
  • Applications
  • Features
For both supply and demand side applications
Restore power efficiently while keeping people safe and processes operational
Ensure safe power recovery while switching utility feeds
Avoid downtime by understanding root causes of acute or chronic power events, and prevent future occurrences
Increase lifetime of equipment, mitigating effects of poor power quality
Save money by reducing energy spend. Use actionable data to optimize operations, avoid peak demand or power factor penalties or errors in utility bills
Demand current I1, I2, I3, I4, I5Peak demand currentsDemand power P, Q, SPeak demand power PM, QM, SMCalculated active and reactive energy (+/- W.h, +/- VAR.h) metering type
EN 50160 compliance checkingIEEE 519 harmonic limitIEC 61000-4-30 class A compliance reportingIEEE 519 compliance reporting waveform capture total demand distortion total harmonic distortion up to the 63rd harmonic up to the 127th harmonic with software disturbance direction detection dip, swell and transient half cycle data acquisition transient detection (20 s) power quality analysis
Voltage sags and swellsCurrent sags and swellsVoltageCurrentFrequencyActive and reactive power totalApparent power totalActive and reactive power per phaseApparent power per phasePower factor totalPower factor per phaseActive and reactive energyApparent energyHarmonic distorsion (I THD & U THD) type of measurement
100 ms 6 cycles at 60 Hz 120 V AC typical400 ms 24 cycles at 60 Hz 240 V AC typical1200 ms 72 cycles at 60 Hz 480 V AC typical ride-through time
1024 samples/cycle sampling rate
1024 samples/cycle sampling rate
01 to 20 A measurement current
Voltage (impedance 5 MOhm)5 external CT 0.3 mOhm) input type
57 to 400 V AC 42 to 69 Hz between phase and neutral100 to 690 V AC 42 to 69 Hz between phases measurement voltage
20 to 450 Hz frequency measurement range
8 digital 30 V AC/60 V DC number of inputs
Voltage +/- 0.1 %Current +/- 0.1 % measurement accuracy
4 digital2 form C relay number of outputs
Modbus RTU 2400 to 115200 bps - 2-wireION 2400 to 115200 bps - 2-wireDNP3 2400 to 115200 bps - 2-wireModbus TCP 10/100 Mbit/sION TCP 10/100 Mbit/sDNP3 TCP 10/100 Mbit/sIEC 61850Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/sDHCPDNSDLMS communication port protocol
2 RS485 removable screw terminal block communication port support