SolaHD SDP4-24-100LT SolaHD SDP™ SDP 4-24-100LT DC Power Supply, 85 to 132/176 to 264 VAC/210 to 375 VDC Input, 24 to 28 VDC Output, 100 W

Power Supplies
209107 MFG #: SDP4-24-100LT
SolaHD™
214.74000 / ea
  • Application: Industrial Control, Process Control, Machine Control, Building Automation, Instrumentation
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Cable Size: 20 to 12 Solid or Stranded AWG
  • Case Material: Plastic
  • Catalog Number: SDP4-24-100LT
  • Country of Origin: TW
  • Currency: USD
  • Depth: 2.85 in
  • Efficiency: 88.00 PCT
  • Enclosure: Class 1, IP20
  • Environmental Conditions: 90 RH Humidity Range PCT
  • EU RoHS Indicator: Y
  • Frequency Rating: 47 to 63 HZ
  • Gross Weight Per Pack: 1.0700 lb
  • Gross Weight per Pack Metric: 0.50
  • Gross Weight UOM Metric: kg
  • Height: 4.90 in
  • Height [Metric]: 12.4460 cm
  • Length: 5.60 in
  • Length [Metric]: 14.2240 cm
  • Material: Plastic
  • Mounting: DIN Rail
  • Standard: UL (CANADA AND US), UL 94, UL 508, UL 60950, CUL, CSA-C22.2, CE
  • Standards: RoHS CompliantcULUS ListedUL 508 E61379/60950-1 ListedCSA C22.2 107.1/C22.2 213/NEC Class 2 SDP 4-24-100RTITE Standard Certified/CE IEC/EN60950-1 Compliant
  • Type: Low Power
  • UNSPSC: 39121004
  • UPC 11: 78347215154
  • UPC 12: 783472151547
  • Voltage Rating: 132/264//375 VAC//VDC
  • Width: 3.90 in
  • Width [Metric]: 9.9060 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: SolaHD™
  • Manufacturer: Emerson
  • Amperage Rating: 3.8 A
  • Input Voltage: 85 to 132/176 to 264 VAC/210 to 375 VDC
  • Mounting Type: DIN Rail
  • Output Voltage: 24 to 28 VDC
  • Power Rating: 100 W
QTY
  • Applications
  • Features
Industrial Control, Process Control, Machine Control, Building Automation, Instrumentation
LED Status Indication, -10 to 70 DEG C Operating Temperature, Output Voltage 24 to 28 VDC, Output Current Rating 4.2A
Adjustable output
PowerBoost™ industrial overload design
Overvoltage, short circuit protection
Continuous short circuit protection
Low output noise
Screw terminal connections
<50 mVp-p ripple/noise
>25 ms hold time
>88% typical efficiency
<12 W typical losses
Static 0.5% voltage output, dynamic + 2% voltage output overall voltage regulation
35 VAC power back immunity
Green LED on when voltage output "OK"
Screw terminals 20 to 12 AWG connector size range for solid or stranded conductors
-10 to 60 deg C full power with linear derating to half power from 60 to 70 deg C (convection cooling, no forced air required) operating temperature
-25 to 85 deg C storage temperature
Up to 90% non-condensing relative humidity
>26 VDC but <27.2 VDC auto recovery overvoltage protection
Continuous operation at overload/short circuit up to 1.5 x nominal current continuous overload behavior
Unit is continuously protected against short circuit overload and open circuit protection