Schneider Electric Multi 9™ 60123 Miniature Circuit Breaker, 120 VAC/60 VDC, 5 A, 10 kA Interrupt, 1 Pole, Thermal Magnetic Trip

Circuit Breakers
98349 MFG #: 60123
Square D™
108.63000 / ea
  • Actuator Type: Toggle
  • Alternate Catalog Number: 60123
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: 60123
  • Color: Gray
  • Connection Type: Box Lug
  • Country of Origin: FR
  • Currency: USD
  • Dimensions: 4.21 in H x 0.71 in W x 2.87 in D
  • Enclosure Type: IP20/IP40
  • EU RoHS Indicator: Y
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 11.83
  • Gross Volume per Pack Metric: 193.89
  • Gross Weight Per Pack: 0.2900 lb
  • Gross Weight per Pack Metric: 0.14
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 0.80 in
  • Height [Metric]: 2.0320 cm
  • Item Group: 00915
  • Length: 5.10 in
  • Length [Metric]: 12.9540 cm
  • Material Composition Declaration: https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&pid=826538&lang=en-us
  • Mounting Type: DIN Rail
  • Phase: 1
  • Returnable: N
  • Series: C60N
  • Standards: ARRA CompliantBuy American Act CompliantUL 489 File No. E215117CCC CertifiedCE CertifiedCSA C22.2 No. 5 File No. 179014IEC 60947-2
  • Temperature Rating: -22 to 158 °F
  • Trip Range: 10 to 14X In
  • UNSPSC: 39121603
  • UPC 11: 78590141103
  • UPC 12: 785901411031
  • Warranty Description: Contractual Warranty: 18 months
  • Width: 2.90 in
  • Width [Metric]: 7.3660 cm
  • Wire Size: 14 to 4 AWG
  • Stock Status: NONSTOCK
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 5 A
  • Interrupt Rating: 10 kA
  • Trip Type: D-Curve/Thermal Magnetic
  • Voltage Rating: 240 VAC/60 VDC
  • Number Of Poles: 1
Schneider Electric 60123 MINIATURE CIRCUIT BREAKER 120V 5A,10 to 14 times ampere rating,35mm DIN rail,5A,60 V DC-125 V DC-12...240 V AC,60 V DC-125 V DC-12...240 V AC,73 mm,Box Lug Box Lug,C60,C60 UL489,miniature circuit-breaker,C60,Multi 9,D,IP40 (Case) - IP20 (Terminals),UL 489 - CSA C22.2 No.5
QTY
  • Features
ON/OFF INDICATION
Fast closing allows increased withstand to the high inrush currents of some loads
Trip free mechanism contacts cannot be held in the I-ON position when the circuit breaker is tripped automatically
Positive indication of contact disconnect
Green mechanical indication on front face of circuit breaker shows that all poles are open
Allows locking in O-OFF position using padlock attachment