Schneider Electric TeSys® LUCA32BL 3-Phase Standard Starter Control Switch With Class 10 Solid State Reset, 3 Poles

Starter Renewal Parts
291236 MFG #: LUCA32BL
Schneider Electric
153.65000 / ea
  • Alternate Catalog Number: LUCA32BL
  • Application: Motor control;motor protection
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: LUCA32BL
  • Coil Voltage: 24 V DC;20...27 V DC 24 V in operation;14.5 V DC 24 V drop-out
  • Country of Origin: FR
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 27.03
  • Gross Volume per Pack Metric: 442.94
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.2600 lb
  • Gross Weight per Pack Metric: 121.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536308000
  • Height: 10.0000 in
  • Height [Metric]: 10.0000 cm
  • Item Group: 22397
  • Length: 8.0000 in
  • Length [Metric]: 8.0000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=640676&lang=en-us
  • Mounting: FRONT SIDE,PLUG-IN
  • Power Supply: 24 VDC
  • Reset Type: SOLID STATE (CLASS 10)
  • Returnable: Y
  • Series: LUCA
  • Size: 2.36 in
  • Specifications: 600 VAC, 32 A, 18.5 kW, 50/60 Hz, 8 to 32 A Full Load Current, 24 VDC Coil
  • Sub Brand: TESYS
  • Substitute Product Catalog Number: LUFN02
  • Type: 3-Phase Solid State Standard
  • UNSPSC: 43201542
  • UPC 11: 78590122222
  • UPC 12: 785901222224
  • Voltage Rating: 600 V CONFORMING TO UL 508-690 V CONFORMING TO IEC 60947-1-600 V CONFORMING TO CSA C22.2 NO 14
  • Warranty Description: Contractual Warranty:18 months
  • Width: 5.3000 in
  • Width [Metric]: 5.3000 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Schneider Electric
  • Manufacturer: Schneider Electric
  • Number Of Poles: 3
  • Suitable For Use With: ASILUFC5, ASILUFC51, LUFC00 and LUFN Communication Module
QTY
  • Applications
  • Features
Motor control;motor protection
EARTH FAULT PROTECTION-PROTECTION AGAINST OVERLOAD AND SHORT-CIRCUIT-MANUAL RESET-PROTECTION AGAINST PHASE FAILURE AND PHASE IMBALANCE
IP20 front panel and wired terminals and IP40 front panel outside connection zone
Front side plug-in mounting location
Earth fault protection, manual reset protection against overload and short circuit protection against phase failure and phase imbalance
Provide basic protection requirements for motor starters
Earth fault protection, manual reset protection against overload and short circuit protection against phase failure and phase imbalance
Provide basic protection requirements for motor starters
14.2 times the FLA setting 8 A to 32 A
Class 10, frequency limit 40 - 60 Hz, temperature compensation -13 to 158 deg F (-25 to 70 deg C) conforming to UL 508 overload tripping class
Standard - contains solid state overload relay and control power source