Schneider Electric TeSys™ D LC1D IEC Contactor With Protective Cover, 24 VDC Coil, 18 A Max Load, 3NO, 3 Poles

NEMA & IEC Contactors
164125 MFG #: LC1D183BL
Schneider Electric
241.73000 / ea
  • Alternate Catalog Number: LC1D183BL
  • Application: Resistive load;motor control
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: LC1D183BL
  • Coil Power Rating: 10 kW
  • Connection Type: Spring Clamp
  • Contact Rating: 18 A at 600 VAC
  • Country of Origin: ID
  • Currency: USD
  • Dimensions: 3.9 in H x 1.77 in W x 3.98 in D
  • Enclosure Type: Open
  • EU RoHS Indicator: Y
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 43.34
  • Gross Volume per Pack Metric: 710.21
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 1.3300 lb
  • Gross Weight per Pack Metric: 602.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536490065
  • Height: 5.5000 in
  • Height [Metric]: 15.0000 cm
  • Item Group: 22354
  • Length: 12.3000 in
  • Length [Metric]: 40.0000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=614154&lang=en-us
  • Mounting: RAIL-PLATE
  • Mounting Type: Surface
  • Number of Auxiliary Contacts: 1NO-1NC
  • Operating Cycles: 30000000
  • Operating Temperature: -4 to 140
  • Returnable: Y
  • Series: D-Line LC1D
  • Size: 101 MM,45 MM,99 MM
  • Standard: 850 A°C IEC 60695-2-1,CSA C22.2 NO 14-EN 60947-4-1-EN 60947-5-1-IEC 60947-4-1-IEC 60947-5-1-UL 508,IP20 FRONT FACE IEC 60529,LROS (LLOYDS REGISTER OF SHIPPING)-BV-GOST-RINA-CCC-CSA-GL-UL-DNV,V1 UL 94
  • Sub Brand: TESYS D
  • Substitute Product Catalog Number: LAD9V2
  • Terminal Type: Spring
  • UNSPSC: 39121529
  • UPC 11: 78590123434
  • UPC 12: 785901234340
  • Warranty Description: Contractual Warranty:18 months
  • Wattage: 2.5/0.8 W
  • Width: 11.0000 in
  • Width [Metric]: 30.0000 cm
  • Stock Status: NONSTOCK
  • Brand: Schneider Electric
  • Manufacturer: Schneider Electric
  • Coil Voltage: 24 VDC
  • Contact Configuration: 3NO
  • Maximum Load Current: 25 A
  • Type: CONTACTOR
  • Number Of Poles: 3
QTY
  • Applications
  • Features
Resistive load;motor control
Built-in bidirectional peak limiting diode suppressor
25 A at 140 deg F power circuit, 10 A at 140 deg F signaling circuit conventional-free air thermal current
300 A at 440 V power circuit conforming to IEC 60947/140 A AC signaling circuit conforming to IEC 60947-5-1/250 A DC signaling circuit conforming to IEC 60947-5-1 IRMs rated making capacity
300 A at 440 V power circuit conforming to IEC 60947 rated breaking capacity
35 A gG at 690 V coordination type 2-power circuit/50 A gG at 690 V coordination type 1 power circuit/10 A gG signaling circuit conforming to IEC 60947-5-1 associated fuse rating
2.5 mOhm at 50 Hz - Ith 25 A power circuit average impedance
65.45 to 88.55 ms opening/20 to 30 ms closing operating time
3600 cycles/hr at <=140 deg F (60 deg C) operating rate
Built-in bi-directional peak limiting diode suppressor coil technology
2.4 W at 68 deg F (20 deg C) inrush power
2.4 W at 68 deg F (20 deg C) hold-in power consumption
40 ms time constant
TH protective treatment
3 pollution degree
-4 to 158 deg F permissible ambient air temperature around the device, -76 to 176 deg F storage temperature
9842.52 ft without derating in temperature operating altitude
1562 deg F (850 deg C) conforming to IEC 60695-2-1 fire resistance
V1 conforming to UL 94 flame retardance
Vibrations contactor open 2 gn, 5 to 300 Hz/vibrations contactor closed 4 gn, 5 to 300 Hz/shocks contactor closed 15 gn for 11 ms and shocks contactor open 6 gn for 11 ms mechanical robustness
25 to 400 Hz signaling circuit frequency
5 mA signaling circuit minimum switching current