FERRAZ MPDB67531 PDB 1P AL INTERMED

Single Pole Distribution Blocks
969888 MFG #: MPDB67531
Ferraz Shawmut
146.86000 / ea
  • Alternate Catalog Number: MPDB67531
  • Application: Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points
  • ARRA Compliant: X
  • Buy American Compliant: X
  • Catalog Number: MPDB67531
  • Color: Black
  • Conductor Range: 2/0-#14 , #6-#14
  • Connection: Box To Box
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 3.25 in H x 1.85 in W x 5 in D
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 18.52
  • Gross Weight Per Pack: 0.6000 lb
  • Gross Weight per Pack Metric: 0.27
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536904000
  • Height: 3.25 in
  • Height [Metric]: 82.5500 mm
  • Length: 3.08 in
  • Length [Metric]: 78.2320 mm
  • Mounting: Direct Screw Mount
  • Number Of Conductors: 2 , 10
  • Number Of Terminals: 1
  • Primary Connections|Pole: 2
  • Secondary Connection|Pole: 10
  • Series: MPDB
  • Short Circuit Current Rating: 100 kA
  • Size: 3.08 x 1.85 x 3.25 in
  • Standard: UL Listed - File E352417 CSA Certified - Class 6228 01 RoHS Compliant
  • Standards: RoHS CompliantUL File No. E352417CSA Class 6228-01, File No. 069363_0_000CE CertifiedUL94-V0 Flammability
  • Type: Open-Style Power Distribution Blocks
  • UNSPSC: 39121410
  • UPC 11: 78200145394
  • UPC 12: 78200145394
  • Width: 1.85 in
  • Width [Metric]: 46.9900 mm
  • Stock Status: NONSTOCK
  • Brand: Ferraz Shawmut
  • Manufacturer: Ferraz Shawmut
  • Amperage Rating: 350 A
  • Material: Polycarbonate
  • Voltage Rating: 600 VAC
  • Wire Size: 14 to 2/0 AWG
  • Number Of Poles: 1
QTY
  • Applications
  • Features
Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points
• Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field witho ut the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block • Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated • Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “Seethrough,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools • Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A • Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block
Aluminum connectors accept both aluminum or copper wire while copper connectors accept copper wire only
Connectors are all 1-piece tin plated
Insulators are virtually unbreakable, made of glass-filled polycarbonate
See-through, hinged safety covers provide a greater degree of safety and shock resistance where required
Hinged covers can be installed without tools
1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL 508A
Polycarbonate safety covers provide dead-front protection
One cover is needed for each pole
Each cover has a test probe hole in the center for circuit checking
14 to 2/0 AWG Al line, 14 to 6 AWG Al load