Sentron™ 5SY5116-7 Miniature Supplementary Protector, 400 VAC/220 VDC, 16 A, 10 kA Interrupt, 1 Pole

Supplementary Protectors
234942 MFG #: 5SY5116-7
Siemens
60.60000 / ea
  • Alternate Catalog Number: 5SY5116-7
  • Application: SUPPLEMENTARY PROTECTION
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: 5SY5116-7
  • Connection: Identical wire screw connections on line and load side.
  • Connection Type: Line/Load Side/Screw
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 90 mm H x 18 mm W x 70 mm D
  • Enclosure Type: IP20
  • EU RoHS Indicator: C
  • Frame: 5SY5
  • Frequency Rating: 50 Hz
  • Gross Volume Per Pack: 9.90
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 0.3580 lb
  • Gross Weight per Pack Metric: 0.16
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 3.27 in
  • Height [Metric]: 8.3058 cm
  • Length: 3.66 in
  • Length [Metric]: 9.2989 cm
  • Material: N/A
  • Mounting Type: DIN Rail
  • Returnable: Y
  • Standard: UL 1077, CSA 22.2 NO. 235, CE, EN 60 898, IEC/EN 60 947-2
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCE MarkedcULus ListedCSA 22.2 No. 235IEC/EN 60898IEC/EN 60947-2UL 1077 File No. E116386
  • Sub Brand: SENTRON
  • Temperature Rating: -25 to 45 °C
  • Trip Range: 18.08 to 23.2 A
  • Type: Miniature
  • UNSPSC: 39121601
  • UPC 11: 75455487853
  • UPC 12: 754554878539
  • Width: 0.83 in
  • Width [Metric]: 2.1006 cm
  • Wire Size: 14 to 4 AWG
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 16 A
  • Interrupt Rating: 10 kA
  • Trip Type: Thermal Magnetic
  • Voltage Rating: 230/400 VAC
  • Number Of Poles: 1
SIEMENS 5SY5116-7 SUPPLEMNTRY PROTECTOR
QTY
  • Applications
  • Features
SUPPLEMENTARY PROTECTION
Type C characteristic is for general device protection in control circuits. Magnetic trip point - 5 to 10 times In rating. Thermal trip point - 1.13 to 1.45 protector rating.
Excellent current limiting and selectivity characteristics
Terminals offer protection against contact with fingers or the back of the hand according to the German accident prevention regulations VBG 4/BGV A2
Combined terminals enable a simultaneous connection of busbars and feeder cables
Uniform components that can be quickly mounted individually
The handle locking device virtually prevents any unauthorized operation of the handle
Rapid connection of the feeder cable in front of the busbar
Identical terminals at both sides for an optional infeed from the top or the bottom
Identical wire screw-on line and load side
No tool required for mounting or dismounting
Supports a fast and comfortable removal from the assembly
Trip indication
Type C characteristic is for general device protection in control circuits
35 mm DIN-rail mounting
5 to 10 times magnetic trip point rating
1.13 to 1.45 thermal trip point protector rating
230/400 VAC/220 VDC