Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 15 A, 2 kA Interrupt, 3 Poles, Magnetic Trip

Motor Protection Circuit Breakers
806587 MFG #: 3RV27114AD10
Siemens
311.13000 / ea
  • Actuator: selector switch
  • Alternate Catalog Number: 3RV2711-4AD10
  • Application: For system protection
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: 3RV27114AD10
  • Connection: screw-type terminals
  • Connection Type: Screw
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 144 mm H x 45 mm W x 97 mm D
  • Enclosure Type: IP00/IP20
  • Environmental Conditions: 80 -50 C
  • EU RoHS Indicator: C
  • Frame: S00
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 53.80
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 1.0300 lb
  • Gross Weight per Pack Metric: 0.47
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536304000
  • Height: 4.20 in
  • Height [Metric]: 10.6680 cm
  • Length: 6.10 in
  • Length [Metric]: 15.4940 cm
  • Mounting Type: DIN Rail/Snap-On/Threaded
  • Operating Temperature: 60 to -20 °C
  • Power Rating: 11 kW
  • Replaced Catalog Number: 3RV1721-4AD10
  • Returnable: Y
  • Standards: CCC CertifiedCSA C22.2 File No. 5-02UL 489EAC ApprovedCE CertifiedVDE ApprovedRoHS CompliantBureau Veritas CertifiedLloyd's RegisteredRMRS ApprovedEN 60715
  • Sub Brand: Sirius
  • Temperature Rating: -20 to 60 °C
  • Trip Range: 15/208 A
  • Type: 3RV2 circuit breaker
  • UNSPSC: 39121601
  • UPC 11: 66264392285
  • UPC 12: 662643922851
  • Width: 2.10 in
  • Width [Metric]: 5.3340 cm
  • Wire Size: 14 to 10 AWG
  • Stock Status: NORMALLY STOCKED
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 16 A
  • Interrupt Rating: 4 kA
  • Trip Type: Thermomagnetic
  • Voltage Rating: 690 VAC
  • Number Of Poles: 3
Siemens 3RV27114AD10 TMCB UL489 S00 15A SCREW
QTY
  • Applications
  • Features
For system protection
Can optionally be fed from the top or from below
Minimization of energy losses through optimization of the bimetal trip units
Reduction of inherent power loss
Less heating of the control cabinet
Smaller control cabinet air conditioners can be used
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks)
4000 W at 230 VAC, 7500 W at 400 VAC, 7500 W at 500 VAC, 11000 W at 690 VAC
100 kA at 240 VAC, 55 kA at 400 VAC, 10 kA at 500 VAC, 4 kA at 690 VAC
15 A thermal overload release, 208 A instantaneous overcurrent release
Without auxiliary switch