Square D™ Qwik-Gard® QOB230GFI Ground-Fault Circuit Breaker, 120/240 VAC, 30 A, 10 kA Interrupt, 2 Poles

Ground-Fault Circuit Breakers
33850 MFG #: QOB230GFI
Square D™
435.79000 / ea
  • Alternate Catalog Number: QOB230GFI
  • Application: Not rated
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: QOB230GFI
  • Connection: Pressure Plate
  • Connection Type: Pressure Plate
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 2.91 in L x 1.5 in W x 4.12 in H
  • EU RoHS Indicator: Y
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 40.81
  • Gross Volume per Pack Metric: 668.75
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.8800 lb
  • Gross Weight per Pack Metric: 400.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536200040
  • Height: 5.5880 in
  • Height [Metric]: 5.5880 cm
  • Item Group: 00015
  • Length: 13.4620 in
  • Length [Metric]: 13.4620 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=400929&lang=en-us
  • Mounting Type: Bolt-On
  • Operating Temperature: 40 °C
  • Phase: 1 ph
  • Returnable: Y
  • Standard: UL LISTED - CSA CERTIFIED
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL 489CSA 22.2 No. 144PPROP65: Cancer and Reproductive Harm - www.P65warnings.ca.gov
  • Sub Brand: QO
  • Substitute Product Catalog Number: NQ30L2C
  • Temperature Rating: 40 °C
  • Type: Ground Fault
  • UNSPSC: 39121603
  • UPC 11: 78590156303
  • UPC 12: 785901563037
  • Warranty Description: Contractual Warranty:18 months
  • Width: 8.8900 in
  • Width [Metric]: 8.8900 cm
  • Wire Size: 14 to 10 AWG/14 to 8 AWG
  • Stock Status: NORMALLY STOCKED
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 30 A
  • Interrupt Rating: 10 kA
  • Trip Type: Thermal Magnetic
  • Voltage Rating: 120/240 VAC
  • Number Of Poles: 2
QTY
  • Applications
  • Features
Not rated
GROUND FAULT PROTECTinG (CLASS A 6MA) BOLT-ON
Qwik-Gard® GFCIs provide the same branch circuit protection as standard QO™ circuit breakers
They are longer than standard QO® circuit breakers and thus require more gutter space
Class A devices must trip at 6 mA of ground fault current and above and hold below 4 mA of ground fault current
For use with NQOD panelboards/interiors
14 to 10 AWG copper, 14 to 8 AWG copper/aluminum wire
Common trip
Ground fault protecting class A 6 mA