• Features
LED indicator on steady: relay energised, no timing in progress;LED indicator 80 % ON and 20 % OFF flashing: timing in progress;LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
Multifunction, dual function or single function
Multi-range (7 selectable ranges)
Multi-voltage
Solid state or relay output options
Cadmium free contacts material
Selector switch on front panel control type
50/60 Hz (+/-5%) supply frequency
5.31 to 8.85 in-lbf (0.6 to 1 Nm) conforming to IEC 60947-1 tightening torque
Self-extinguishing housing material
+/-0.5% conforming to IEC 61812-1 repeat accuracy
100 MOhm at 500 VDC conforming to IEC 60664-1 insulation resistance
+/-0.05% temperature drift
+/-0.2% voltage drift
100 ms with load in parallel typical 30 ms typical Impulse duration
<=3 VA at 240 VAC power consumption in voltage
<=1.5 W at 240 VDC power consumption
250 VAC maximum switching voltage
<=2000 VA breaking capacity
2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 dielectric strength
<100 ms delay response