Schneider Electric XPSUAT33A3AP XPSafety Module, 5 A
Safety Relays
1324101
MFG #: XPSUAT33A3AP
Square D™
639.58000
/ ea
- Brochure URL - 032ab4e9301e805eb1a3e49576c5c0726278af87.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADID0001241_2D-left.dwg(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL(Install Instructions 1 URL)
- Install Instructions 1 URL - 11003_JOD7UZKYL3C8T1VQ.zip(Install Instructions 1 URL)
- Install Instructions 1 URL - 11003_ZMU9JIR21YS8PXCE.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_62FIES4YRUDQZAXJ.pdf(Service Manual URL)
- Service Manual URL - 11003_C3PRMK8UH2QBZ4YE.pdf(Service Manual URL)
- Spec Sheet URL - 11003_6OIEARCJ2DUQ3W9G.pdf(Spec Sheet URL)
- User Manual URL - 11003_4CK9PQW0S6DERBXZ.pdf(User Manual URL)
- User Manual URL - 11003_5ZWMRASVX7DYOCHK.pdf(User Manual URL)
- Applications
- Features
For monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety sw, For a broad range of machines of the general mechanical engineering |
22.5 & 45 mm width |
2 rows of terminals both on the top and bottom side (screw or spring removable terminals) |
Transparent sealable lid in front face, to protect the selector switches from manipulation |
Side connection for extension unit without need for external wiring except for XPSUAB & XPSUEP |
DIN-rail & direct wall mounting possibility |
24 Vac/dc + Wide Range Power-Supply from 48 to 240 Vac/dc (only 2 supply variants for full coverage now) |
XPSUAT safety module name |
Monitoring antivalent contactsFor emergency stop, guard and light curtain monitoringMonitoring of pressure-sensitive 4-wire protective devices safety module application |
Emergency stop button with 2 NC contactsGuard monitoring with 1 or 2 limit switchesMonitoring 2 PNP sensorsMagnetic switch monitoringLight curtain monitoringRFID switchMonitoring of electro-sensitive protection equipment (ESPE)Sensing mat/edgesProximity sensor monitoringMonitoring 1 PNP + 1 NPN sensor function of module |
Automatic/manual/monitored type of start |
Automatic/manual/monitored type of start |
Internal, electronic input protection type |
3 NO3 NO1 NC safety outputs |
21 safety inputs |
500 Ohm maximum wire resistance |
0 to 900 s time delay range |
4 pulsed output control outputs |
Pulsed output for diagnostics Z1, 20 mASemiconductor output Z2, 20 mA input/output type |
24 V relay output minimum output voltage |