Schneider Electric Square D™ GV2RT20 Circuit Breaker Thermal Magnetic Manual Starter, 3 Poles, IP20 Enclosure
Manual Starters
PDW~6402834
MFG #: GV2RT20
Square D™
0.00000
/ ea
Schneider Electric Square D™ Manual Starter, Circuit Breaker Thermal Magnetic, Series: TeSys™ GV2RT, 690 VAC, 18 A, 50/60 Hz Frequency, 4/7.5/9/15 kW Motor, 3 Pole, Setting: 13 to 18 A, Manual Reset, 3 ph, Screw Clamp Connection, Class 10 Ambient Compensated Overload Relay, Rocker Lever Control, IP20 Enclosure, 100000 Cycles Operating Cycles, -20 to 60 deg C Operating, 89 mm H x 45 mm W x 78.5 in D Dimensions
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=8007786360Den&ext=webp(360 Degree View URL)
- Install Instructions 1 URL - 11003_D2G7BZUV4P1CJIHE.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADPD0003993_2D-right.dwg(Computer~Aided [CAD|BIM] Model URL)
- Service Manual URL - files?p_enDocType=Circularity+Profile&p_File_Name=EoLI_ENVEOLI121004EN_V5.pdf(Service Manual URL)
- Spec Sheet URL - 11003_Q0JWTC79L28DSYIU.pdf(Spec Sheet URL)
- Video - https://www.youtube.com/embed/YkQwgPFibOM(Video)
- Tech Bulletin URL - 11003_8G547S3DJIOHPNLZ.pdf(Tech Bulletin URL)
- Tech Bulletin URL - 11003_R8DPHVO6FAXJE9S2.pdf(Tech Bulletin URL)
- Applications
- Features
Food and Beverage, Material Working, Material Handling, Small Pumps and Packaging |
IK04,IP20 CONFORMING TO IEC 60529 |
Manual and local control, when the motor circuit-breaker is used on its own and automatic and remote control when combined with a contactor |
Motor protection provided by thermal magnetic devices built into the circuit breaker |
No live parts are accessible to direct finger contact |
The addition of an undervoltage trip enables the motor circuit breaker to be tripped if voltage is lost |
The addition of a shunt trip enables remote control of tripping |
The control for the open or enclosed motor circuit breaker can be locked in the "N/C" position using 3 padlocks |
The system manages motors and other electrical loads up to 40 hp |
Up to 20 modules and 1 bus coupler (up to 112 cm L) |
One click mounting on DIN rail and no need for control wiring on modules |
All adjustments and setting are digitized, no mechanical dials or dip switches |
All adjustments and setting are digitized, no mechanical dials or dip switches |
Energy monitoring at load level |
Detect and solve issues before your machine stops |
Gain better insight to the operation and performance of the machine |
Decrease time to market, helping improve project profitability |
4 kW at 220/230 VAC, 7.5 kW at 400/415/440 VAC, 9 kW at 440 VAC, 9 kW at 500 VAC, 10/15 kW at 690 VAC motor rating |