Schneider Electric GV2RT06 MANUAL STARTER 600VAC 1
Manual Starters
266520
MFG #: GV2RT06
Schneider Electric
192.41000
/ ea
Schneider Electric GV2RT06 MANUAL STARTER 600VAC 1.6AMP IEC,-20...60 deg.C,100000 cycles,690 V AC 50/60 Hz conforming to IEC 60947-2,690 V AC 50/60 Hz conforming to IEC 60947-2,GV2RT,circuit breaker,IP20 conforming to IEC 60529,TeSys,TeSys GV2,by screws-by clips
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=8033093360Den&ext=webp(360 Degree View URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_D2G7BZUV4P1CJIHE.pdf(Install Instructions 1 URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADPD0003993_2D-right.dwg(Computer~Aided [CAD|BIM] Model URL)
- Brochure URL - 115967977b38aa63fd29e8e8024eb8003e40dffe.pdf(Brochure URL)
- Tech Drawing URL - 983ade7bc77391301429fe620f7a2ffdf71c0d8f.pdf(Tech Drawing URL)
- Service Manual URL - files?p_enDocType=Circularity+Profile&p_File_Name=EoLI_ENVEOLI121004EN_V5.pdf(Service Manual URL)
- Video - https://www.youtube.com/embed/YkQwgPFibOM(Video)
- ROHS Compliance URL - Schneider_Electric_GV2RT06_RoHS.pdf(ROHS Compliance URL)
- Tech Bulletin URL - 11003_8G547S3DJIOHPNLZ.pdf(Tech Bulletin URL)
- Spec Sheet URL - 11003_375VQFNCZEIB9PWG.pdf(Spec Sheet URL)
- Tech Bulletin URL - 11003_R8DPHVO6FAXJE9S2.pdf(Tech Bulletin URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Applications
- Features
TRANSFORMER-MOTOR |
IK04,IP20 CONFORMING TO IEC 60529 |
Manual and local control, when the motor circuit-breaker is used on its own and automatic and remote control when combined with a contactor |
Motor protection provided by thermal magnetic devices built into the circuit breaker |
No live parts are accessible to direct finger contact |
The addition of an undervoltage trip enables the motor circuit breaker to be tripped if voltage is lost |
The addition of a shunt trip enables remote control of tripping |
The control for the open or enclosed motor circuit breaker can be locked in the "N/C" position using 3 padlocks |
The system manages motors and other electrical loads up to 40 hp |
Up to 20 modules and 1 bus coupler (up to 112 cm L) |
One click mounting on DIN rail and no need for control wiring on modules |
No auxiliary wiring required, thanks to full connectivity over fieldbus |
All adjustments and setting are digitized, no mechanical dials or dip switches |
Energy monitoring at load level |
Detect and solve issues before your machine stops |
Gain better insight to the operation and performance of the machine |
Decrease time to market, helping improve project profitability |
0.18 kW at 220/230 VAC, 0.25 kW at 220/230 VAC, 0.37 kW at 400/415/440/500 VAC, 0.55 kW at 400/415/440/550 VAC, 0.75 kW at 500/690 VAC, 1.1 kW at 690 VAC motor rating |