Schneider Electric GV2ME216, IP20 enclosure
Manual Starters
1393272
MFG #: GV2ME216
Square D™
246.48000
/ ea
Schneider Electric GV2ME216, 690 VAC, 23 A, 50 to 60 Hz Frequency, 9 to 18.5 kW Motor, Setting: 17-23 , Pushbutton Control, IP20 Enclosure, 25 cycles Operating Cycles, -4 to 140 deg F Operating, 3.50 in H x 1.77 in W x 3.09 in D Dimensions
- 360 Degree View URL - index.html?pid=11003&id=15636290360Den&ext=webp(360 Degree View URL)
- Brochure URL - b271386a410f0e59146c773fcdaf71c5c7b1c4ee.pdf(Brochure URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Install Instructions 1 URL - 11003_YPBI174FEM5DJL2X.pdf(Install Instructions 1 URL)
- Service Manual URL - files?p_enDocType=Circularity+Profile&p_File_Name=EoLI_ENVEOLI121004EN_V5.pdf(Service Manual URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=GV2ME016_2D-isometric.dxf(Computer~Aided [CAD|BIM] Model URL)
- Video - https://www.youtube.com/embed/JTJzM9Yur5o(Video)
- Tech Bulletin URL - 11003_8G547S3DJIOHPNLZ.pdf(Tech Bulletin URL)
- User Manual URL - files?p_enDocType=User+guide&p_File_Name=1672546-08.pdf(User Manual URL)
- Spec Sheet URL - 11003_6NH8TD5Y7OZLAIRE.pdf(Spec Sheet URL)
- Applications
- Features
For 100 000 cycles AC-3, For 3-phase motor applications 9kW |
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit |
The basic motor starter GV2ME controls motors with full load currents up to 32A |
The GV2P, high performance manual starter, offers a higher withstand rating and visible trip indication for convenience |
The GV2P has an additional UL 508 type E rating as a stand alone self-protected manual combination starter |
Single phase sensitivity |
Magnetic instantaneous short-circuit protection |
Test trip mechanism |
The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost |
The addition of a shunt trip enables remote control of tripping |
Fingersafe terminals (meets IP20 standards) |
Fingersafe terminals (meets IP20 standards) |
AC network type |
35 mm symmetrical DIN rail clippedPanel screwed with adaptor plate) fixing mode |
Any position operating position |
100 % 230/240 V AC 50/60 Hz IEC 60947-275 % 690 V AC 50/60 Hz IEC 60947-275 % 500 V AC 50/60 Hz IEC 60947-250 % 440 V AC 50/60 Hz IEC 60947-240 % 400/415 V AC 50/60 Hz IEC 60947-2 ics rated service short-circuit breaking capacity |
17 to 23 A thermal protection adjustment range |
327 A magnetic tripping current |
690 V AC 50/60 Hz IEC 60947-2 ui rated insulation voltage |
6 kV IEC 60947-2 uimp rated impulse withstand voltage |