• Features
The housing is made from high quality die-cast aluminum and powder coated painted black; Gold plated contacts eliminate high resistance tarnishing; May be mounted for right or left hand pull; Each captive terminal will accept (2) 14 AWG stranded wires; Each switch is supplied with a fibreflex gasket which provides an oil tight seal upon installation; For added protection against corrosive environments a neoprene gasket is available as an accessory item by ordering part number 02005-540; There are two 3/4 IN NPT conduit openings; The maximum cable recommended cable length is 200 FT with a maximum interval support of 10 FT; This switch can be installed on various conveyor installations and provides a constant access for emergency or normal stopping; The rugged construction and long term reliability makes this cable pull switch well suited to function within various
This switch is particularly competent for use in emergency stop applications as well as for ordinary circuit control
The housing is made from high quality die-cast aluminum and powder coated painted black
Manual reset with positive break contacts
Gold plated contacts eliminate high resistance tarnishing
May be mounted for right or left hand pull
Captive terminal will accept (2) 14 AWG stranded wires
Each switch is supplied with a fibreflex gasket which provides an oil tight seal upon installation
For added protection against corrosive environments a neoprene gasket is available as an accessory item by ordering part number 02005-540
There are two 3/4 in NPT conduit openings
The maximum cable recommended cable length is 200 FT with a maximum interval support of 10 FT
The mechanical life of the switch is 150000 operations
This switch can be installed on various conveyor installations and provides a constant access for emergency or normal stopping
The rugged construction and long term reliability makes this cable pull switch well suited to function within various environments
A600/N300 Heavy duty rating
-40 to 85 deg C storage
Operating temperatures at 0 deg C are based on the absence of freezing moisture and liquids
6 A 110 - 120 VAC, 3 A 220 - 240 VAC, 1.5 A 440 - 480 VAC, 1.2 A 550 - 600 VAC at power factor 0.35 or less, 2.2 A 115 - 125 VDC, 1.1 A 230 - 250 VDC at inductive loads as specified in section 125 of industrial control devices, controllers and assemblies, ANSI/NEMA ICS 2-1988
60, 30, 15, 12 A inrush current, 10 lb trip force, 1.8 lb operating force between 10 ft supports
2669 old catalog number
Slack cable style, '6 A/1.2 A at 110 - 120/550 - 600 VAC, 2.2 A/1.1 A at 115 - 125/230 - 250 VDC