Decora® LevNet RF™ WSS20-G9N Rocker Switch Receiver With Color Change Kit, 902 MHz, <0.5 W
Decorative Switches
861197
MFG #: WSS20-G9N
Leviton®
66.29000
/ ea
- Catalog URL - Decora_LevNet_RF_WSS20_G9N_Datasheet_1.pdf(Catalog URL)
- http://www.leviton.com(Seller Home Page URL)
- Owners Manual URL - Decora_LevNet_RF_WSS20_G9N_Manual.pdf(Owners Manual URL)
- Safety Data Sheet URL - MSDS.pdf(Safety Data Sheet URL)
- Install Instructions URL - Decora_LevNet_RF_WSS20_G9N_Installation.pdf(Install Instructions URL)
- Spec Sheet 1 URL - Decora_LevNet_RF_WSS20_G9N_Datasheet_1.pdf(Spec Sheet 1 URL)
- Spec Sheet 2 URL - Decora_LevNet_RF_WSS20_G9N_Specification_Sheet_2.pdf(Spec Sheet 2 URL)
- Spec Sheet URL - 12203_FN6B37XMDRHC10VL.pdf(Spec Sheet URL)
- Applications
- Features
Residential |
Repeater Disabled |
Decora® design aesthetics, intuitive rocker switch with return to center design |
No new wiring required, the LevNet RF™ wall switch receivers simply replaces the existing light switch and communicates with self-powered switches and sensors via radio 902 MHz frequency |
Vacancy switching, provides pushbutton manual-on/off light switching of each light load at any time |
Maximize energy savings, when paired with LevNet RF™ PIR occupancy Sensor, the LevNet RF™ wall switch receivers contain all sensor settings |
Manual on/auto on, auto on/auto off, walk-through timer, auto time out selections of 2 min for testing (10, 20 or 30 min) |
Presentation/viewing mode, turn lights Off and keep them Off while room is occupied (i.e. for slide or film presentations), automatically returns to normal when manually switched back On or room becomes vacant and time delay expires |
Walk-through feature, maximizes energy savings by assuring a 2.5 min time out if motion is not present after 2.5 min in auto-on mode |
Standard size for seamless installation, LevNet RF™ wall switch receivers fit in a standard single-gang wallbox |
Required wiring, neutral and non-neutral models available, non-neutral requires 25 W minimum load |
Zero cross relay switches at the zero crossing point of the AC power curve to ensure maximum contractor life and compatibility with electronic ballasts |
Energy savings and efficiency, lowest power consumption of any RF device less than 1/2 W per 120 VAC device and less than 2/3 W per 277 VAC device annually approximately 70% savings over other RF devices |
Air gap switch, assures A/C power disconnects for safety on no neutral switch |
Color change kits, white, ivory and light almond included for design flexibility, ease of ordering, inventory and cost control |
10 A load rating for commercial lighting circuits |
EnOcean® technology enabled, for LevNet RF™ communication from self-powered lighting controls |
HIS (high inrush stability), arcing design for use with all commercial ballasts |
Retrofit energy saving bi-level lighting with occupancy sensor control, replace two light switches with LevNet RF™ wall switch receivers pair both with self-powered RF PIR sensor, set the first LevNet RF™ wall switch to auto-on/auto-off and the second to manual-on/auto-off |
Product compatibility, LevNet RF™ 902 MHz products |
Repeater disabled |