Safety extension module provides additional safety outputs for a primary safety device |
Features four delayed 6-amp switching channels for connection to control reliable machine power interrupt circuits |
For use in functional controlled stop category 1 application per NFPA 79 and EN418 |
Contact status outputs are provided for connection to the primary safety devices monitoring input |
Housed in a narrow, 22.5 mm (0.9 in) DIN-rail-mountable module |
Polycarbonate primary housing |
100 mA power consumption |
1.0 s +/-30% off-delay response time |
30 ms recovery time |
Transient voltage/reverse polarity supply protection |
10 to 55 Hz at 0.35 mm vibration |
50 deg C operating temperature |
90% at 50 deg C relative humidity |
Fixed terminal type |
Inputs is 1 = output of primary device |
4 outputs |
3 green LED indicators power ON, K1/K2 energized |
AgSnO2 contacts |