Banner Engineering AT-FM-10K Duo-Touch® AT Series Safety Control Module, 150 mA, 2NO Contact Form

Safety Relays
134728 MFG #: AT-FM-10K
BANNER®
408.18000 / ea
Banner Engineering Duo-Touch® Safety Control Module, Series: AT Series, 150 mA, 3 W, 50/60 Hz, 2NO, DIN Rail Mount, Removable Terminal, NEMA 1/IP20, 0 to 50 deg C, 84 mm H x 22.5 mm W x 118 mm D
QTY
  • Features
Diverse-redundant microcontrollers; Monitors two Banner STB Self-Checking Optical Touch Buttons, or two mechanical push buttons; Two redundant, forced-guided (mechanically linked) output contacts rated at 6 AMP; Feedback input monitors external machine control elements; 5 indicator LEDs for Power, Fault, input 1, input 2 and Output; Din-rail-mountable 22.5 MM wide housing with removable terminal blocks; 500 MS simultaneity requirement for touch-/push button operation; Supply protection circuitry: Protected against transient voltages and reverse polarity; Overvoltage category: Output relay contact voltage of 1 V to 150 V AC/DC - Category III, Output relay contact voltage of 151 V to 250 V AC/DC - Category II; AgNi and 5 UM gold-plated output contacts
Polycarbonate primary housing
25 mA at 24 VDC (1 NO/1 NC per channel) safety input - dual channel (dry contact), 25 mA at 24 VDC (1 complimentary PNP pair per channel) safety input - dual channel (solid-state)
Type IIIc; Category 4; Ple; SIL 3 design rating
1000000 cycles at 250 VA electrical life
90% at 50 deg C relative humidity
Simultaneous <500 ms (500 ms typical) input operation
2 NO (6 A) output configuration
20000000 operations mechanical life
35 ms response time
Transient voltage/reverse polarity supply protection
24 VAC/VDC +/-15% supply voltage
10 to 55 Hz at 0.35 mm vibration
2 pollution degree
AgNi 5 um gold-plated contacts
2 redundant safety relay contacts outputs
Diverse-redundant microcontrollers
Two redundant, forced-guided (mechanically linked) output contacts rated at 6 A
Feedback input for monitoring external machine control elements
5 indicator LEDs for power, fault, input 1, input 2 and output
Protected against transient voltages and reverse polarity