Amprobe® VolTect™ 5XP-A Compact Digital Multimeter, 1000 VDC, 750 VAC, 200 mA, 20 MOhm, 600 VAC/VDC, 200 mA, 20 MOhm
Multimeters
PDW~3669784
MFG #: 5XP-A
Amprobe
121.99000
/ ea
Amprobe 5XP-A Digital Multimeter provides superior features and accuracy in a smaller form factor. The 5XP-A has unique features such as VolTect™ non-contact voltage detection and our exclusive Magne-Grip™ holster that frees both hands for work. The 5XP-A is the perfect choice for residential, commercial and general troubleshooting applications
- Catalog URL - IDW_DOCUMENT_35c2ba63ef3858341ccf2a957632a656eb0f5c4baf8e6d33cb7a6b65d0805534.pdf(Catalog URL)
- http://www.fluke.com(Seller Home Page URL)
- Owners Manual URL - 11095_KSXAPOZDY8J2QUM6.jpg(Owners Manual URL)
- Line Drawing URL - IDW_DOCUMENT_1525153029941.png(Line Drawing URL)
- Install Instructions URL - IDW_DOCUMENT_1520575062912.pdf(Install Instructions URL)
- Spec Sheet URL - 11095_Spec sheet reference.pdf(Spec Sheet URL)
- Video - https://www.youtube.com/embed/mRwsxmn2P-s(Video)
- Applications
- Features
residential, commercial and general troubleshooting applications |
VolTect™ non-contact voltage (NVC) detection |
27 ranges/10 functions |
Battery load test with 1.5 VDC and 9 VDC capabilities |
Data hold |
Maximum/minimum record maximum and minimum values |
VolTect™ non-contact voltage (NVC) detection |
Low battery indication |
+/-1.5% RDG + 1 digit DC current accuracy |
+/-2% RDG + 5 digits AC current accuracy |
+/-1% RDG + 4 digits at 200 Ohm and 2 to 200 kOhm, +/-1.5% RDG + 4 digits at 2 MOhm, +/-2% RDG + 5 digits at 20 MOhm resistance accuracy |
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 |
100 uV, 0.1 uA, 100 mOhm, 1 mV diode test resolution |
AC current range- 200 uA, 2 mA, 20 mA, 200 mA with accuracy of +/-(2 % rdg + 5 dgts), DC current range- 200 uA, 2 mA, 20 mA, 200 mA with accuracy of +/-(1.5 % rdg + 1 dgts) |
Resistance range- 200 Ohm, 2 kOhm, 20 kOhm, 200 kOhm with accuracy of +/-(1% rdg + 4 dgts) , 2 MOhm with accuracy of +/-(1.5% rdg + 4 dgts), 20 MOhm with accuracy of (2% rdg + 5 dgts) |
AC voltage range- 200 mV, 2 V, 20 V, 200 V, 750 V with accuracy of +/- (1.5 % rdg + 5 dgts) |
DC voltage range - 200 mV, 2 V, 20 V, 200 V, 1000 V with accuracy of +/- (1% rdg + 1 dgt) |