Appleton® EFS150-2023 U-Line® Pin and Sleeve Receptacle Assembly, 125 VAC, 20 A, 3 Poles, 2 Wires

Explosion Proof Pin & Sleeve Receptacles
17112 MFG #: EFS150-2023
Appleton™
576.73000 / ea
  • Application: For ECP And NCP Mating Plugs
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: EFS150-2023
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.0005 lb
  • Gross Weight per Pack Metric: 2.19
  • Gross Weight UOM Metric: kg
  • Height: 4.50 in
  • Height [Metric]: 11.4300 cm
  • Length: 7.00 in
  • Length [Metric]: 17.7800 cm
  • Material: Copperfree (4/10 Of 1 PCT Maximum) Aluminum Receptacle, Malleable Iron Mounting Box
  • Mounting: Surface Mount With 1/2 IN Dead-End Hub
  • NEMA Rating: NEMA 3, 3R
  • Standard: Class I, Division 1 And 2, Groups B, C, D; Class II, Division 1 And 2, Groups F, G; Class III; UL Listed: E10784, E81751; UL Standard: 1203, 1010, 894; CSA Standard: C22.2 No. 25, C22.2 No. 30, C22.2 No. 42, C22 No.159; CSA Certified: 038644
  • Standards: Class I, Division 1 and 2, Groups B, C, D, Class II, Division 1 and 2, Groups F, G, Class III, CSA C22.2 No.25, 30, 42, 159File No. 038644, RoHS Complaint, UL 1203, 1010, 894 File No. E10784, E81751 Listed
  • Sub Brand: U-Line
  • Type: 1-Gang Receptacle With Mounting Box
  • UNSPSC: 39121406
  • UPC 11: 78138127870
  • UPC 12: 781381278706
  • Width: 7.00 in
  • Width [Metric]: 17.7800 cm
  • Stock Status: NONSTOCK
  • Brand: Appleton™
  • Manufacturer: Appleton
  • Amperage Rating: 20 A
  • Number of Wires: 2
  • Voltage Rating: 125 VAC
  • Number Of Poles: 3
QTY
  • Applications
  • Features
For ECP And NCP Mating Plugs
Explosionproof, dust-ignitionproof; Factory sealed, external seals not required in most areas, arcing is safely confined to receptacle interior; For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps; Suitable for use in Class I, Division 1, Group B when used with external seals (seals must be placed within 2 IN from each conduit opening, seals are not required in Class I, Division 2 locations); Spring cover; Glass-filled reinforced polyester insulating blocks
Explosion proof, dust-ignition proof
Factory sealed, external seals not required in most areas, arcing is safely confined to receptacle interior
Suitable for use in Class I, Division 1, Group B when used with external seals (seals must be placed within 2 IN from each conduit opening, seals are not required in Class I, Division 2 locations
Spring cover
Glass-filled reinforced polyester insulating blocks
Energized receptacle contacts deeply recessed to reduce danger of accidental touching
Unique blade-type, brass contacts exert constant pressure along entire contact surface and provide superior electrical contact
Insulators provide superior dielectric and mechanical strength and lowest arc tracking
Surface mount
1/2 in dead-end hub
1-gang
For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps
Copper free (4/10 of 1 PCT) aluminum receptacle
Epoxy powder coat
With mounting box