O-Z/Gedney IBC-350LS-20AC 3-1/2 IN GNDG IN

Ground Bushings
22195 MFG #: IBC-350LS-20AC
O-Z/Gedney
41.15000 / ea
  • Application: For Rigid Conduit And IMC
  • ARRA Compliant: C
  • Buy American Compliant: N
  • Catalog Number: IBC-350LS-20AC
  • Connection: Set-Screw
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: N
  • Finish: Zinc Plated
  • Gross Weight Per Pack: 0.5000 lb
  • Gross Weight per Pack Metric: 0.23
  • Gross Weight UOM Metric: kg
  • Height: 0.96 in
  • Height [Metric]: 24.3840 mm
  • Length: 8.00 in
  • Length [Metric]: 20.3200 cm
  • Lug Type: Tin Coated Aluminum Lay-In
  • Series: IBC-LS-AC
  • Size: 3-1/2 in
  • Standard: Third Party Certification: UL File Number E-24264, CSA 009795, Applicable Third Party Standards: UL 467, CSA C22.2 No.41, Federal Specification W-F-408E, NEMA : FB-1
  • Standards: ARRA CompliantCEC CertifiedCSA 009795/C22.2 No. 41Federal Specification W-F-408ENEC CertifiedNEMA FB-1UL 467/E-24264
  • Temperature Rating: 150 °C
  • Throat: Insulated
  • Turning Radius: 3-1/16 in
  • Type: Type IBC-LS-AC Insulated Grounding Bushing With Lug
  • UNSPSC: 39121312
  • UPC 11: 78312630394
  • UPC 12: 783126303940
  • Width: 5.20 in
  • Width [Metric]: 13.2080 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: O-Z/Gedney
  • Manufacturer: O-Z/Gedney
  • Diameter: 4-1/2 in
  • Material: Malleable Iron Body, Aluminum Lug, Steel Clamping Screw And Set Screws
  • Maximum Wire Size: 2/0 AWG Stranded
  • Minimum Wire Size: 14 AWG Solid
  • Trade Size: 3-1/2 in
QTY
  • Applications
  • Features
For Rigid Conduit And IMC
O-Z/Gedney malleable iron bushings incorporate a thermoplastic insulator and an aluminum lay-in lug grounding lug; They are used to protect wires and cables at entry and exit of conduit and to provide for grounding of the conduit; Insulating liner material is UL V-O rated (self extinguishing); The plastic liner is tough, it won’t chip, crack, swell or shrink, resists corrosion, chemicals and temperature extremes; Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation; Set-screw provided with each fitting locks bushing in any desired position; UL listed for use with copper or aluminum grounding conductors; Lugs not sold separately
Aluminum Lay-In-Lug™ for copper/aluminum conductors
Temperature rating 302 deg F
Insulating liner material is self-extinguishing
The plastic liner is tough
It won't chip, crack, swell or shrink
It resists corrosion, chemicals and temperature extremes
Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation
Lugs not sold separately
Set screw provided with each fitting locks bushing in any desired position