Siemens MT0100A CONTROL TRANSFORMER,100VA,240/480-120V,
Control Transformers
243320
MFG #: MT0100A
Siemens
93.29000
/ ea
- Alternate Catalog Number: US2:MT0100A
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: MT0100A
- Connection Type: Screw
- Country of Origin: MX
- Currency: USD
- Dimensions: 8.4 in L x 8.2 in W x 8.6 in H
- Enclosure Type: Open
- EU RoHS Indicator: C
- Gross Volume Per Pack: 80.00
- Gross Volume UOM: in
- Gross Weight Per Pack: 5.0000 lb
- Gross Weight per Pack Metric: 2.27
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8504314065
- Height: 8.6000 in
- Height [Metric]: 21.8440 cm
- Length: 8.4000 in
- Length [Metric]: 21.3360 cm
- Maximum Amperage Rating: 0.29 A
- Maximum Input Current: 0.29@240VAC A
- Mounting Type: Panel
- Returnable: Y
- Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantcUL ListedUL ListedCSA Certified
- Temperature Rating: 55 °C
- Type: Class MT
- UNSPSC: 39121026
- UPC 11: 75455402680
- UPC 12: 754554026800
- Width: 8.2000 in
- Width [Metric]: 20.8280 cm
- Stock Status: NORMALLY STOCKED
- Brand: Siemens
- Manufacturer: Siemens
- Frequency Rating: 60 Hz
- Phase: 1 ph
- Power Rating: 100 VA
- Primary Voltage: 240/480 VAC
- Secondary Voltage: 120 VAC
- Brochure URL - Control%20Power%20Transformers%20Class%20MT%20MTG.pdf(Brochure URL)
- Catalog 1 URL - Siemens_MTG0150A_Catalog_1.pdf(Catalog 1 URL)
- Catalog URL - IDW_DOCUMENT_d0b84c93d1400d2945d5515a84aebd2fa1ba7ca8447c7478037320ac9201939a.pdf(Catalog URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=US2:MT0100A&language=en(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=PDPS&mlfbs=US2:MT0100A&language=en(Spec Sheet URL)
- User Manual URL - man(User Manual URL)
- Features
Epoxy-encapsulated, fuse clips, Integrally molded barriers, jumpers supplied |
Epoxy encapsulated (50 to 750 VA), epoxy resin impregnated (1 to 5 kVA) |
Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments |
Fuse clips (most models), factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add-on fuse block or kit |
Integrally molded barriers, between terminals and transformer, protect against electrical creepage, up to 30% greater terminal contact area permits low loss connections, extra deep barriers reduce the chance of shorts from frayed leads or careless wiring |
Terminals, molded into the transformer, are difficult to break during wiring, a full quarter-inch of thread on the #10-32 terminal screws prevents stripping and pullout |
Jumpers supplied, two jumper links are standard with all transformers which can be wired for dual primary voltages |
Laminations are built with silicon steel to minimize core losses and to increase optimum performance and efficiency |
Insulation materials are of the highest rating available for the temperature class |
Robust design |
240/480, 230/460, 220/440 VAC primary voltage |
120/115/110 VAC secondary voltage |
0.29 A max at 240 VAC |