Dongan 35-LM020 35 Series Dry General Purpose Ventilated Isolation Transformer, 240/480 VAC Primary, 24/48 VAC Secondary
Isolation Transformers
PDW~555106
MFG #: 35-LM020
Dongan
159.00000
/ ea
- Application: For Indoor Or Outdoor Use
- Catalog Number: 35-LM020
- Country of Origin: USA
- Gross Weight Per Pack: 15.0000 lb
- Height: 7.5 in
- KVA Rating: 0.25 kVA
- Maximum Amperage Rating: 520m/1/5.2/10.4 A
- Mounting: Wall
- Standard: UL Listed File E3210, CSA Certified File LR 560
- Standards: UL File No. E3210, CSA File No. LR 560, RoHS Complaint
- Type: General Purpose, Ventilated, Dry-Type, Type LM, Double Wound
- UNSPSC: 39121029
- UPC 11: 78249035721
- Width: 4.63 in
- Stock Status: NONSTOCK
- Brand: Dongan
- Manufacturer: Dongan Electric
- Frequency Rating: 50/60 Hz
- Primary Voltage: 240 x 480 VAC
- Secondary Voltage: 24/48 VAC
Dongan Isolation Transformer, Dry General Purpose Ventilated, Series: 35 Series, 240/480 VAC Primary, 24/48 VAC Secondary, 0.25 kVA, 50/60 Hz, 1 Phase, 1/0.52 A Maximum, Lead Wire, Wall Mount, 100% Duty Cycle, 105 deg C, NEMA 3R, 55 deg C, 7.5 in H x 4.63 in W x 4 in D
- Applications
- Features
For Indoor Or Outdoor Use |
Features: UL Listed, File E3210, CSA Certified, File LR 560; Copper Windings And Copper Lead Wire Terminations Used Throughout; Series 35 Has A UL Class 105 ° C Insulation System With 55 ° C Temperature Rise At A Maximum Ambient Of 40 ° C; This Insures A Long Life And Cool Operating Temperatures; NEMA-3R, Wall Mount Enclosure Suitable For Indoor Or Outdoor Use; May Be Used In Banks Of 2 Or 3 Units For Standard Three Phase Voltages And Nonstandard, Open Delta Auto-Transformer Applications; Multiple Knockouts Provide Convenient Conduit Entry And Exit Locations Through The Front Access Wiring Compartment; Ground Studs Provided For Bonding Compatibility With Both Metallic And Nonmetallic Conduit; Nonstandard Designs Are Available By Consulting The Factory Or Your Dongan Representative; Double Wound, Isolation Type Transformers; Temperature Rise: 55 ° C Temper |
Copper windings and copper lead wire terminations used throughout |
Series 35 has a UL class 105 deg C insulation system with 55 deg C temperature rise at a maximum ambient of 40 deg C |
This insures a long life and cool operating temperatures |
May be used in banks of 2 or 3 units for standard three phase voltages and nonstandard, open delta autotransformer applications |
Multiple knockouts provide convenient conduit entry and exit locations through the front access wiring compartment |
Ground studs provided for bonding compatibility with both metallic and nonmetallic conduit |
Nonstandard designs are available by consulting the factory or your dongan representative |
Double wound |
Type M |
1/0.52 A (primary), 10.4/5.2 A (secondary) |