Dongan 35-LM020 35 Series Dry General Purpose Ventilated Isolation Transformer, 240/480 VAC Primary, 24/48 VAC Secondary

Isolation Transformers
PDW~555106 MFG #: 35-LM020
Dongan
159.00000 / ea
  • Application: For Indoor Or Outdoor Use
  • Catalog Number: 35-LM020
  • Country of Origin: USA
  • Gross Weight Per Pack: 15.0000 lb
  • Height: 7.5 in
  • KVA Rating: 0.25 kVA
  • Maximum Amperage Rating: 520m/1/5.2/10.4 A
  • Mounting: Wall
  • Standard: UL Listed File E3210, CSA Certified File LR 560
  • Standards: UL File No. E3210, CSA File No. LR 560, RoHS Complaint
  • Type: General Purpose, Ventilated, Dry-Type, Type LM, Double Wound
  • UNSPSC: 39121029
  • UPC 11: 78249035721
  • Width: 4.63 in
  • Stock Status: NONSTOCK
  • Brand: Dongan
  • Manufacturer: Dongan Electric
  • Frequency Rating: 50/60 Hz
  • Primary Voltage: 240 x 480 VAC
  • Secondary Voltage: 24/48 VAC
Dongan Isolation Transformer, Dry General Purpose Ventilated, Series: 35 Series, 240/480 VAC Primary, 24/48 VAC Secondary, 0.25 kVA, 50/60 Hz, 1 Phase, 1/0.52 A Maximum, Lead Wire, Wall Mount, 100% Duty Cycle, 105 deg C, NEMA 3R, 55 deg C, 7.5 in H x 4.63 in W x 4 in D
QTY
  • Applications
  • Features
For Indoor Or Outdoor Use
Features: UL Listed, File E3210, CSA Certified, File LR 560; Copper Windings And Copper Lead Wire Terminations Used Throughout; Series 35 Has A UL Class 105 ° C Insulation System With 55 ° C Temperature Rise At A Maximum Ambient Of 40 ° C; This Insures A Long Life And Cool Operating Temperatures; NEMA-3R, Wall Mount Enclosure Suitable For Indoor Or Outdoor Use; May Be Used In Banks Of 2 Or 3 Units For Standard Three Phase Voltages And Nonstandard, Open Delta Auto-Transformer Applications; Multiple Knockouts Provide Convenient Conduit Entry And Exit Locations Through The Front Access Wiring Compartment; Ground Studs Provided For Bonding Compatibility With Both Metallic And Nonmetallic Conduit; Nonstandard Designs Are Available By Consulting The Factory Or Your Dongan Representative; Double Wound, Isolation Type Transformers; Temperature Rise: 55 ° C Temper
Copper windings and copper lead wire terminations used throughout
Series 35 has a UL class 105 deg C insulation system with 55 deg C temperature rise at a maximum ambient of 40 deg C
This insures a long life and cool operating temperatures
May be used in banks of 2 or 3 units for standard three phase voltages and nonstandard, open delta autotransformer applications
Multiple knockouts provide convenient conduit entry and exit locations through the front access wiring compartment
Ground studs provided for bonding compatibility with both metallic and nonmetallic conduit
Nonstandard designs are available by consulting the factory or your dongan representative
Double wound
Type M
1/0.52 A (primary), 10.4/5.2 A (secondary)