HPS Drive Isolation DM075KK

Drive Isolation Transformers
526619 MFG #: DM075KK
HPS (Hammond Power Solutions)
3815.81000 / ea
  • Application: Variable Speed Drives.
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: DM075KK
  • Cooling: Convection cooled
  • Country of Origin: MUL
  • Currency: USD
  • Enclosure: NH3-N3R - Indoor or Outdoor
  • EU RoHS Indicator: Y
  • Gross Volume per Pack Metric: 96.52
  • Gross Volume UOM Metric: kg
  • Gross Weight Per Pack: 570.0000 lb
  • Gross Weight per Pack Metric: 570.00
  • Harmonization Tariff Schedule Code: 8504330040
  • Height: 38.00 in
  • KVA Rating: 75 kVA
  • Length: 26.00 in in
  • Mounting: Floor Mount
  • Number Of Phases: 3
  • Standard: CSA, UL
  • Standards: UL Listed, CSA Certified, RoHS Complaint
  • Sub Brand: HPS Tribune™
  • Temperature Rating: 40 °C
  • Type: Transformers Drive Isolation
  • UNSPSC: 39121029
  • UPC 11: 80342305242
  • UPC 12: 803423052423
  • Warranty Description: 10 Year Warranty
  • Width: 25.00 in in
  • Stock Status: NONSTOCK
  • Brand: HPS (Hammond Power Solutions)
  • Manufacturer: Hammond Power Solutions
  • Frequency Rating: 60 Hz
  • Primary Voltage: 480 V
  • Secondary Voltage: 480Y V
HPS Drive Isolation Transformers are designed to meet the rugged demands of both AC and DC variable speed drives and also to provide the required voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds. A duty cycle of one start for every two hours is permitted.
QTY
  • Applications
  • Features
Variable Speed Drives.
Designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds. Comes standard in an indoor/outdoor enclosure with a coil mounted thermal warning switch.
Designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds
Comes standard in an indoor/outdoor enclosure with a coil mounted thermal warning switch
The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load
Neutral terminal for field connection (on applicable units)
Aluminum wound
High grade non-aging, fully processed silicon steel laminations or better coil
ST-20 compliant taps
ANSI 61 UL 50 gray enclosure finish
40 deg C maximum