HPS Drive Isolation DM063KDC Standard Drive Isolation Transformer, 480 VAC Delta Primary, 240Y VAC Secondary, 63 kVA

Drive Isolation Transformers
971729 MFG #: DM063KDC
HPS (Hammond Power Solutions)
4345.39000 / ea
  • Application: Variable Speed Drives.
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: DM063KDC
  • Connection Type: Lug/Pad
  • Cooling: Convection cooled
  • Country of Origin: MUL
  • Currency: USD
  • Dimensions: 21 in L x 26 in W x 38 in H
  • Enclosure: NH3-N3R - Indoor or Outdoor
  • Enclosure Type: NEMA 3R
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 585.0000 lb
  • Gross Weight per Pack Metric: 265.36
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504330040
  • Height: 38.00 in
  • Height [Metric]: 96.5200 cm
  • Insulation: 220
  • KVA Rating: 63
  • Length: 26.00 in
  • Length [Metric]: 66.0400 cm
  • Mounting: Floor Mount
  • Mounting Type: Floor
  • Number Of Phases: 3
  • Standard: CSA, UL
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL File No. E112313CSA File No. LR3902
  • Sub Brand: Standard Drive Isolation Transformer
  • Temperature Rating: Typical 30 Average/ 40 Maximum °C
  • Type: Transformers > Drive Isolation
  • UNSPSC: 39121001
  • UPC 11: 80342300344
  • UPC 12: 803423003449
  • Width: 25.00 in
  • Width [Metric]: 63.5000 cm
  • Stock Status: NONSTOCK
  • Brand: HPS (Hammond Power Solutions)
  • Manufacturer: Hammond Power Solutions
  • Frequency Rating: 60 Hz
  • Phase: 3 pH
  • Power Rating: 63 kVA
  • Primary Voltage: 480 V
  • Secondary Voltage: 240Y V
HPS drive isolation transformers, are designed to meet the rugged demands of both AC and DC variable speed drives and also provide the required voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds. Drive isolation transformers are sized to match standard motor horsepower and voltage ratings.
QTY
  • Applications
  • Features
Variable Speed Drives.
Designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds. Comes standard in an indoor/outdoor enclosure with a coil mounted thermal warning switch.
Neutral terminal for field connection
Designed to withstand overcurrent of 150% of the rated load for 60 s or 200% of the rated load for 30 s
Comes standard in an indoor/outdoor enclosure with a coil mounted thermal warning switch