DRIVE 3PH 440KVA 460-460 CU

Drive Isolation Transformers
1049265 MFG #: DM440JJC
HPS (Hammond Power Solutions)
22562.93000 / ea
  • Application: Variable Speed Drives.
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: DM440JJC
  • Connection Type: Lug/Pad
  • Cooling: Convection cooled
  • Country of Origin: MUL
  • Currency: USD
  • Dimensions: 38 in L x 48-1/2 in W x 59 in H
  • Enclosure: NJ2-N3R - Indoor or Outdoor
  • Enclosure Type: NJ2-N3R Indoor/Outdoor
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 2550.0000 lb
  • Gross Weight per Pack Metric: 1156.68
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504330040
  • Height: 59.00 in
  • Height [Metric]: 149.8600 cm
  • Insulation: 220
  • KVA Rating: 440
  • Length: 48.50 in
  • Length [Metric]: 123.1900 cm
  • Mounting: Floor Mount
  • Mounting Type: Floor
  • Number Of Phases: 3
  • Standard: CSA, UL
  • Standards: UL ListedCSA CertifiedRoHS Compliant
  • Sub Brand: Standard Drive Isolation Transformer
  • Temperature Rating: Typical 30 Average/ 40 Maximum °C
  • Type: Transformers > Drive Isolation
  • UNSPSC: 39121001
  • UPC 11: 80342300450
  • UPC 12: 803423004507
  • Width: 38.40 in
  • Width [Metric]: 97.5360 cm
  • Stock Status: NONSTOCK
  • Brand: HPS (Hammond Power Solutions)
  • Manufacturer: Hammond Power Solutions
  • Frequency Rating: 60 Hz
  • Phase: 3 pH
  • Power Rating: 440 kVA
  • Primary Voltage: 460 V
  • Secondary Voltage: 460Y V
HPS Drive Isolation Transformers are designed to meet the rugged demands of both AC and DC variable speed drives and also to provide the required voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds. A duty cycle of one start for every two hours is permitted.
QTY
  • Applications
  • Features
Variable Speed Drives.
Designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds. Comes standard in an indoor/outdoor enclosure with a coil mounted thermal warning switch.
Designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds
Comes standard in an indoor/outdoor enclosure with a coil mounted thermal warning switch
The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load
Neutral terminal for field connection (on applicable units)
Copper winding
High grade non-aging, fully processed silicon steel laminations or better coil
ST-20 compliant taps
ANSI 61 UL 50 gray enclosure finish
40 deg C maximum