Square D™ Surgelogic™ SSP01EMA12S EMA Surge Protective Device, 120/240 VAC, 200 kA SCCR, 1 ph

AC Surge Protective Devices
PDW~12049458 MFG #: SSP01EMA12S
Square D™
0.00000 / ea
  • Alternate Catalog Number: SSP01EMA12S
  • Application: Low Voltage Products and Systems, Building Automation and Control, Industrial Automation and Control and Critical Power, Cooling and Racks Applications
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: SSP01EMA12S
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 5123.25
  • Gross Volume per Pack Metric: 83954.70
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.1461 lb
  • Gross Weight per Pack Metric: 14.61
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536308000
  • Height: 57.6000 in
  • Height [Metric]: 57.6000 cm
  • Item Group: 08464
  • Length: 23.9000 in
  • Length [Metric]: 23.9000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=455794503&lang=en-us
  • Returnable: Y
  • UNSPSC: 39121634
  • UPC 11: 78590107523
  • UPC 12: 785901075233
  • Voltage Rating: 120/240 VAC
  • Width: 29.7000 in
  • Width [Metric]: 29.7000 cm
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Phase: 1 Phase
Square D™ Surgelogic™ Surge Protective Device, Series: EMA, 120/240 VAC Electrical Rating, 3 Wires, 200 kA Short Circuit, 120 kA Peak Surge Current, 20 kA Nominal Discharge, LED Indicator, 1 ph, Environmental Conditions: 149 deg F Temperature deg F, NEMA 4X Enclosure, Surface Mounting, Lug Terminal, Stainless Steel, 11.7 in W x 9.4 in D x 22.67 in H Dimensions
QTY
  • Applications
  • Features
Low Voltage Products and Systems, Building Automation and Control, Industrial Automation and Control and Critical Power, Cooling and Racks Applications
NEMA 1 or 4X rating
High energy suppression circuit that provides 10 modes of suppression from 100000 to 480000 peak amps of surge current rating per phase
Advanced diagnostics allow for visual indication/testing of the suppressor's functionality
Suppression status alarms provide multiple methods of alarm notification
Coordinated fuse technology allows disconnection methods for thermal and high current events
External panel SPDs mount adjacent to the equipment through a conduit connection and as close to the circuit breaker as possible in order to reduce lead lengths and improve surge suppression