Telemecanique LUB32 Non-Reversing Motor Starter, 3-Poles, IP20/IP40 Enclosure
Starters
97197
MFG #: LUB32
Schneider Electric
399.81000
/ ea
- Alternate Catalog Number: LUB32
- Amperage Rating: 32 A
- Application: TESYS U SIMPLE MOTOR STARTER
- ARRA Compliant: N
- Auxiliary Contact Rating: 1NO-1NC
- Buy American Compliant: N
- Catalog Number: LUB32
- Connection: Screw clamp terminals
- Connection Type: Screw Clamp
- Control Type: Screw Clamp
- Country of Origin: FR
- Currency: USD
- Dimensions: 145 mm H x 45 mm W x 126 mm D
- EU RoHS Indicator: Y
- Frequency Rating: 40/60 Hz
- Gross Volume Per Pack: 78.79
- Gross Volume per Pack Metric: 1291.13
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 1.8900 lb
- Gross Weight per Pack Metric: 846.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 8536504000
- Height: 5.5000 in
- Height [Metric]: 5.5000 cm
- Item Group: 22396
- Length: 16.9000 in
- Length [Metric]: 16.9000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=640638&lang=en-us
- Motor Power: 2 to 25 hp
- Mounting: DIN RAIL OR PANEL MOUNT
- Operating Cycles: 15000000 Cycles
- Operating Temperature: -25 to 70 °C
- Phase: 3 pH
- Power Supply: DETERMINED BY CONTROL UNIT SELECTION
- Reset Type: MANUAL (AUTO WITH ACCESSORIES)
- Returnable: Y
- Series: LUB
- Setting: 145 mm H x 45 mm W x 126 mm D
- Size: 126 MM,154 MM,45 MM in
- Specifications: 600 VAC, 3 ph, 2 to 25 hp, Screw Clamp Connection, 1NO-1NC, IP20/IP40/Open Enclosure, 15000000 Operating Cycles, -25 to 70 Operating Cycle, 40/60 Hz, 32 A, 24 VDC, DIN Rail/Panel Mount, Manual
- Standard: UL LISTED - CSA CERTIFIED - CE MARKED
- Standards: UL 508, CSA C22.2 No. 14, EN 60947-6-2, IEC 60947-6-2
- Sub Brand: TESYS
- Substitute Product Catalog Number: GVAPB65
- UNSPSC: 39121521
- UPC 11: 78590122181
- UPC 12: 785901221814
- Voltage Rating: 24 VDC
- Wattage: 600 VAC, 3-Phase, 2 to 25 hp, Screw Clamp Connection, 1NO-1NC, IP20/IP40/Open Enclosure, 15000000 Operating Cycles, -25 to 70 Operating Cycle, 40/60 Hz, 32 A, 24 VDC, DIN Rail/Panel Mount, Manual
- Width: 13.8000 in
- Width [Metric]: 13.8000 cm
- Stock Status: NORMALLY STOCKED
- Brand: Schneider Electric
- Manufacturer: Schneider Electric
- Enclosure Type: IP20/IP40
- Type: Non-Reversing
- Number Of Poles: 3
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=8092573360Den&ext=webp(360 Degree View URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=SB115119_2D-bottom.dwg(Computer~Aided [CAD|BIM] Model URL)
- Brochure URL - 115967977b38aa63fd29e8e8024eb8003e40dffe.pdf(Brochure URL)
- 3D Rendering URL - SEproductListV2.html?p=LUB32(3D Rendering URL)
- Catalog URL - IDW_DOCUMENT_70996af6246876088ceaf1f47eba7f0492a975d7b94c784a0928e354f597324b.pdf(Catalog URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=SB115119_3D-simplified.stp(Computer~Aided [CAD|BIM] Model URL)
- Spec Sheet URL - 11003_FP9W0S7DVUB6J2RO.pdf(Spec Sheet URL)
- Spec Sheet 1 URL - Telemecanique_LUB32_Datasheet.pdf(Spec Sheet 1 URL)
- Service Manual URL - 11003_0KNTGY4LUH87Q9WB.pdf(Service Manual URL)
- Install Instructions 1 URL - 11003_5I2W3TPE0MY97HLQ.pdf(Install Instructions 1 URL)
- Service Manual URL - 11003_3B1E5RC6VPAZK927.pdf(Service Manual URL)
- Tech Drawing URL - 11003_Q53NLDUI1OGM7TFS.dxf(Tech Drawing URL)
- Seller Home Page URL - us(Seller Home Page URL)
- User Manual URL - 11003_DQPXI1Z780BOFKMG.pdf(User Manual URL)
- Tech Drawing URL - 11003_WDLGQ896RAZECHN5.dxf(Tech Drawing URL)
- User Manual URL - 11003_K5A94RB37LYJXDNC.pdf(User Manual URL)
- Applications
- Features
TESYS U SIMPLE MOTOR STARTER |
INCLUDES 1N/O AND 1 N/C AUXILIARY CONTACT. |
2 hp at 115 VAC, 5 hp at 230 VAC, 10 hp at 200/230 VAC, 20 hp at 460 VAC, 25 hp at 575/600 VAC |
60 cycles/min operating rate |
6 kV conforming to IEC 60947-6-2 rated impulse withstand voltage |
3 W for control circuit with LUCA, LUCB, LUCC, LUCD and 1.8 W for control circuit with LUCM heat dissipation |
3 ms immunity to microbreaks |
70% 500 ms conforming to IEC 61000-4-11 immunity to voltage dips |
TH protective treatment |
-40 to 85 deg C ambient air temperature for storage |
650 deg C conforming to IEC 60695-2-12 and 960 deg C parts supporting live components conforming to IEC 60695-2-12 fire resistance |
2000 m operating altitude |
10 and 15 gn power poles open conforming to IEC 60068-2-27 shock resistance |
2 gn 5 to 300 Hz power poles open and 4 gn 5 to 300 Hz power poles closed conforming to IEC 60068-2-27 |
8 kV level 3 in open air conforming to IEC 61000-4-2 and 8 kV level 4 on contact conforming to IEC 61000-4-2 resistance to electrostatic discharge |
10 VAC/m 3 conforming to IEC 61000-4-3 resistance to radiated fields |
2 kV class 3 serial link conforming to IEC 61000-4-4 and 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 resistance to fast transients |
10 VAC conforming to IEC 61000-4-6 immunity to radioelectric fields |