Square D™ LUB Self-Protected Starter Power Base, 5.71 in H x 1.77 in W x 4.96 in D
Starters
97201
MFG #: LUB12
Schneider Electric
282.29000
/ ea
- Alternate Catalog Number: LUB12
- Application: TESYS U SIMPLE MOTOR STARTER
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: LUB12
- Connection: Screw clamp terminals
- Country of Origin: FR
- Currency: USD
- Dimensions: 5.71 in H x 1.77 in W x 4.96 in D
- EU RoHS Indicator: Y
- Gross Volume Per Pack: 75.24
- Gross Volume per Pack Metric: 1232.96
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 1.8800 lb
- Gross Weight per Pack Metric: 842.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 8536490065
- Height: 5.2000 in
- Height [Metric]: 5.2000 cm
- Item Group: 22396
- Length: 17.0000 in
- Length [Metric]: 17.0000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=640634&lang=en-us
- Mounting: DIN RAIL OR PANEL MOUNT
- Power Supply: DETERMINED BY CONTROL UNIT SELECTION
- Reset Type: MANUAL (AUTO WITH ACCESSORIES)
- Returnable: Y
- Series: LUB
- Size: 4.96 in
- Specifications: 110 to 240 VAC/VDC, 12 A, 1.7/2 W, 50/60 Hz, 3-Poles, 1NO-1NC
- Standard: CE;UL;CSA;CCC;EAC;ASEFA;ATEX;Marine
- Standards: ABS, ASEFA, ATEX, BV, CCC Certified, CSA C22.2 No. 14 Type E, DNV Certified, EN 60947-6-2, GL, GOST Certified, IEC 60947-6-2, LROS Certified, UL 508
- Sub Brand: TESYS
- Substitute Product Catalog Number: GVAPB65
- Type: Self-Protected
- UNSPSC: 39121521
- UPC 11: 78590122224
- UPC 12: 785901222248
- Voltage Rating: 600 VAC
- Warranty Description: Contractual Warranty:18 months
- Width: 13.5000 in
- Width [Metric]: 13.5000 cm
- Stock Status: NORMALLY STOCKED
- Brand: Schneider Electric
- Manufacturer: Schneider Electric
- Number Of Poles: 3
- Suitable For Use With: Combination Motor Starters
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=8092809360Den&ext=webp(360 Degree View URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=SB115119_2D-bottom.dwg(Computer~Aided [CAD|BIM] Model URL)
- Catalog URL - SquareD_LA7D901_Catalog.pdf(Catalog URL)
- 3D Rendering URL - SEproductListV2.html?p=LUB12(3D Rendering URL)
- Brochure URL - b35b7a2dfd1324536b5f6e4bf14a80bc4dfae8ca.pdf(Brochure URL)
- Spec Sheet 1 URL - SquareD_LUB12_Datasheet.pdf(Spec Sheet 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Install Instructions 1 URL - 11003_5I2W3TPE0MY97HLQ.pdf(Install Instructions 1 URL)
- Spec Sheet URL - 11003_HIG7DNZOK52JETMQ.pdf(Spec Sheet URL)
- Service Manual URL - 11003_JHS6EQNR12OILVXA.pdf(Service Manual URL)
- Service Manual URL - 11003_3B1E5RC6VPAZK927.pdf(Service Manual URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=SB115119_3D-simplified.stp(Computer~Aided [CAD|BIM] Model URL)
- Tech Drawing URL - 11003_Q53NLDUI1OGM7TFS.dxf(Tech Drawing URL)
- Video - https://youtube.com/embed/OaomPiHOkYk(Video)
- Tech Drawing URL - 11003_WDLGQ896RAZECHN5.dxf(Tech Drawing URL)
- User Manual URL - 11003_DQPXI1Z780BOFKMG.pdf(User Manual URL)
- User Manual URL - 11003_K5A94RB37LYJXDNC.pdf(User Manual URL)
- Applications
- Features
TESYS U SIMPLE MOTOR STARTER |
INCLUDES 1N/O AND 1 N/C AUXILIARY CONTACT. |
Suitability for isolation |
10 kA 500 V, 4 kA 690 V, 50 kA 230 V, 50 kA 440 V rated service breaking capacity |
130 mA at 24 VDC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 140 mA at 24 VAC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 150 mA at 24 VDC I maximum while closing with LUCM, 280 mA at 110 to 220 VDC I maximum while closing with LUCA, LUCB, LUCC, LUCD |
35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 75 ms closing with LUCM control circuit operating time |
15000000 cycles mechanical durability, 60 cycles/min operating rate, 6 kV conforming to IEC 60947-6-2 rated impulse withstand voltage, 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1 3 rated insulation voltage |
Control circuit: 7.08-10.62 lbf.in- with screwdriver 0.2 in flat, control circuit: 7.08-10.62 lbf.in - with screwdriver 0.2 in Philips no 1, power circuit: 16.81-22.12 lbf.in- with screwdriver 0.24 in flat, power circuit: 16.81-22.12 lbf.in - with screwdriver 0.24 in Philips no 2 tightening torque |
2 W for control circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W for control circuit with LUCM heat dissipation |
IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1 IP degree of protection |
TH conforming to IEC 60068 protective treatment |
1 kV serial mode 24 to 240 VAC conforming to IEC 60947-6-2, 1 kV serial mode 48 to 220 VDC conforming to IEC 60947-6-2, 2 kV common mode 24 to 240 VAC conforming to IEC 60947-6-2, 2 kV common mode 48 to 220 VDC conforming to IEC 60947-6-2 non-dissipating shock wave, 10 V conforming to IEC 61000-4-6 immunity to radio electric fields |
1.5 hp at 1 phase 115 VAC, 2 hp at 1 phase 230 VAC, 10 hp at 3 phase 575 VAC, 3 hp at 3 phase 230 VAC, 3 hp at 3 phase 200 VAC, 7.5 hp at 3 phase 460 VAC power rating |
-13 to 140 deg F with LUCM/-13 to 158 deg F with LUCA, LUCB, LUCC, LUCD |