Intermatic® T7401B T7000B Electromechanical Mechanical Timer, 3-1/2 hr - 7 Days Time Setting, 125 VAC, 10 hp, 4 Poles

Timers
7806 MFG #: T7401B
Intermatic®
301.83000 / ea
  • Action: 4PST
  • Amperage Rating: 40 A
  • Application: Commercial, Industrial, Residential, Indoor, HVACR
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: T7401B
  • Connection: Screw Terminal
  • Contact Configuration: 4 NO
  • Contact Rating: 40 AMP @ 120 - 480 VAC
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 12-1/2 in H x 8-1/4 in W x 4 in D
  • Electrical Connections: Screw
  • Enclosure: NEMA 1 STEEL
  • Enclosure Type: NEMA 1
  • EU RoHS Indicator: X
  • Gross Weight Per Pack: 8.5900 lb
  • Gross Weight per Pack Metric: 3.70
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 9107008000
  • Height: 9.31 in
  • Height [Metric]: 23.6474 cm
  • Length: 12.60 in
  • Length [Metric]: 32.0040 cm
  • Mounting: Wall Mount
  • Mounting Type: Wall
  • Operating Temperature: -40 to +130 DEG F, -40 to +54 DEG C
  • Series: T7000B
  • Size: 12-1/2 HEIGHT X 8-1/4 WIDTH X 4 DEPTH IN, 31.7 HEIGHT X 21.0 WIDTH X 10.2 CM
  • Standard: cCSAus Certified, HVACR
  • Standards: cCSAus Certified, cULus Listed, HVACR, RoHS Compliant
  • Temperature Rating: -40 to 130 °F
  • Timer Duration: 3-1/2 HR/7 DAYS
  • Timing Range: 3-1/2 HR - 7 DAYS
  • Type: Electromechanical
  • UNSPSC: 39122208
  • UPC 11: 07827546101
  • UPC 12: 07827546101
  • Wattage: 3 W
  • Width: 4.10 in
  • Width [Metric]: 10.4140 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Intermatic®
  • Manufacturer: Intermatic Incorporated
  • Contact Form: 4NO 4PST
  • Horsepower: 10 hp
  • Time Setting: 3-1/2 hr to 7 days
  • Voltage Rating: 125 VAC
  • Number Of Poles: 4
QTY
  • Applications
  • Features
Commercial, Industrial, Residential, Indoor, HVACR
Features: Separate clock motor terminals for switching loads not on-line voltage, Carryover automatically rewinds when power resumes, One hour of rewinding time for every two hours of power outage, 1 Year Warranty
Different ON/OFF programs each day of the week
True 7-day load control with minimum ON/OFF time of 3-1/2 hours
Separate clock motor terminals for switching loads not on line voltage
Carry-over automatically rewinds when power resumes
Minimum of 16-hour carry-over for maintaining preset schedules during power failures
Available with Type 3R rated outdoor metal enclosure or Type 1 rated indoor metal in gray finish with separate grounding terminal
40 A at 120 - 480 VAC (resistive), 40 A at 120/208/240/277 VAC (inductive), 40 A at 120/208/240/277 VAC (tungsten)
2 hp, 24 FLA at 120 VAC, 5 hp, 28 FLA at 240 VAC (1 phase), 7-1/2 hp, 28 FLA at 208 VAC, 10 hp, 28 FLA at 240 VAC (3 phase) motor
60 Hz
3 W power
1000 VA, 120-277 VAC per pole pilot duty
14 - 8 AWG
16 A, 277 VAC electronic ballast
3-1/2 hr/7 days time duration
Without Carry-Over