Schneider Electric GV2RT21 MANUAL STARTER 600VAC 2
Manual Starters
220843
MFG #: GV2RT21
Schneider Electric
239.44000
/ ea
- Alternate Catalog Number: GV2RT21
- Amperage Rating: 23 A
- Application: MOTOR
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: GV2RT21
- Connection: SCREW CLAMP TERMINALS 2 1-6 MMA² SOLID- SCREW CLAMP TERMINALS 2 1.5-6 MMA² FLEXIBLE WITHOUT CABLE END- SCREW CLAMP TERMINALS 2 1-4 MMA² FLEXIBLE WITH CABLE END
- Connection Type: Screw Clamp
- Control Type: Rocker Lever
- Country of Origin: US
- Currency: USD
- Dimensions: 89 mm H x 45 mm W x 78.5 in D
- EU RoHS Indicator: Y
- Frequency Rating: 50/60 Hz
- Gross Volume Per Pack: 23.90
- Gross Volume per Pack Metric: 391.65
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 0.6400 lb
- Gross Weight per Pack Metric: 290.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 8536200020
- Height: 8.6000 in
- Height [Metric]: 8.6000 cm
- Item Group: 22367
- Length: 4.8000 in
- Length [Metric]: 4.8000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=607878&lang=en-us
- Motor Power: 5.5 kW, 9 kW, 11 kW, 18.5 kW
- Mounting: BY SCREWS-BY CLIPS
- Number Of Poles: 3
- Operating Cycles: 100000 Cycles
- Operating Temperature: -20 to 60 °C
- Overload Relay: Class 10 Ambient Compensated
- Phase: 3
- Reset Type: Manual
- Returnable: Y
- Series: TeSys™ GV2RT
- Setting: 17 to 23 A
- Size: 45 MM,78.5 MM,89 MM
- Standard: 960 A°C IEC 60695-2-1,EN/IEC 60947-2-EN/IEC 60947-4-1-UL 60947-4-1-CSA C22.2 NO 60947-4-1,IECEE CB SCHEME-UL-CSA-CCC-EAC-BV-LROS (LLOYDS REGISTER OF SHIPPING),IK04,IP20 IEC 60529
- Sub Brand: TESYS
- Substitute Product Catalog Number: GVAD1010
- UNSPSC: 39121521
- UPC 11: 78590110310
- UPC 12: 785901103103
- Voltage Rating: 690 VAC
- Warranty Description: Contractual Warranty:18 months
- Width: 9.3000 in
- Width [Metric]: 9.3000 cm
- Stock Status: NONSTOCK
- Brand: Schneider Electric
- Manufacturer: Schneider Electric
- Enclosure Type: IP20
- Type: Circuit Breaker Thermal Magnetic
Schneider Electric GV2RT21 MANUAL STARTER 600VAC 23AMP IEC,-20...60 deg.C,100000 cycles,690 V AC 50/60 Hz conforming to IEC 60947-2,690 V AC 50/60 Hz conforming to IEC 60947-2,GV2RT,circuit breaker,IP20 conforming to IEC 60529,TeSys,TeSys GV2,by clips-by screws
- Brochure URL - 4c52c1683b196d4b0bada2503d78649e79c923f4.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADPD0003993_2D-right.dwg(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_D2G7BZUV4P1CJIHE.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- ROHS Compliance URL - Schneider_Electric_GV2RT21_RoHS.pdf(ROHS Compliance URL)
- Spec Sheet URL(Spec Sheet URL)
- Tech Drawing URL - 983ade7bc77391301429fe620f7a2ffdf71c0d8f.pdf(Tech Drawing URL)
- Tech Bulletin URL(Tech Bulletin URL)
- Tech Bulletin URL - 11003_R8DPHVO6FAXJE9S2.pdf(Tech Bulletin URL)
- Video - https://www.youtube.com/embed/JTJzM9Yur5o(Video)
- Tech Bulletin URL - 11003_8G547S3DJIOHPNLZ.pdf(Tech Bulletin URL)
- Service Manual URL - files?p_enDocType=Circularity+Profile&p_File_Name=EoLI_ENVEOLI121004EN_V5.pdf(Service Manual URL)
- Spec Sheet URL - 11003_J75D1I3KLMSY8B9O.pdf(Spec Sheet URL)
- Applications
- Features
MOTOR |
IK04,IP20 CONFORMING TO IEC 60529 |
Manual and local control, when the motor circuit-breaker is used on its own and automatic and remote control when combined with a contactor |
Motor protection provided by thermal magnetic devices built into the circuit breaker |
No live parts are accessible to direct finger contact |
The addition of an undervoltage trip enables the motor circuit breaker to be tripped if voltage is lost |
The addition of a shunt trip enables remote control of tripping |
The control for the open or enclosed motor circuit breaker can be locked in the "N/C" position using 3 padlocks |
The system manages motors and other electrical loads up to 40 hp |
Up to 20 modules and 1 bus coupler (up to 112 cm L) |
One click mounting on DIN rail and no need for control wiring on modules |
No auxiliary wiring required, thanks to full connectivity over fieldbus |
All adjustments and setting are digitized, no mechanical dials or dip switches |
Energy monitoring at load level |
Detect and solve issues before your machine stops |
Gain better insight to the operation and performance of the machine |
Decrease time to market, helping improve project profitability |
5.5 kW at 220/230 VAC, 9/11 kW at 400/415 VAC, 11 kW at 440/500 VAC, 18.5 kW at 690 VAC motor rating |