Schneider Electric GV2ME216, IP20 enclosure

Manual Starters
1393272 MFG #: GV2ME216
Square D™
224.00000 / ea
  • Alternate Catalog Number: GV2ME216
  • Application: For 100 000 cycles AC-3, For 3-phase motor applications 9kW
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: GV2ME216
  • Country of Origin: TH
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 0.01
  • Gross Volume per Pack Metric: 0.16
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 2.9300 lb
  • Gross Weight per Pack Metric: 293.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536200040
  • Height: 1.83 in
  • Height [Metric]: 4.7000 cm
  • Item Group: 22367
  • Length: 3.32 in
  • Length [Metric]: 8.5000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=607658&lang=en-us
  • Returnable: Y
  • Substitute Product Catalog Number: GV2AF02
  • UNSPSC: 39121521
  • Warranty Description: Contractual Warranty:18 months
  • Width: 3.70 in
  • Width [Metric]: 9.5000 cm
  • Stock Status: NONSTOCK
  • Brand: Square D™
  • Manufacturer: Schneider Electric
Schneider Electric GV2ME216, 690 VAC, 23 A, 50 to 60 Hz Frequency, 9 to 18.5 kW Motor, Setting: 17-23 , Pushbutton Control, IP20 Enclosure, 25 cycles Operating Cycles, -4 to 140 deg F Operating, 3.50 in H x 1.77 in W x 3.09 in D Dimensions
QTY
  • Applications
  • Features
For 100 000 cycles AC-3, For 3-phase motor applications 9kW
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit
The basic motor starter GV2ME controls motors with full load currents up to 32A
The GV2P, high performance manual starter, offers a higher withstand rating and visible trip indication for convenience
The GV2P has an additional UL 508 type E rating as a stand alone self-protected manual combination starter
Single phase sensitivity
Magnetic instantaneous short-circuit protection
Test trip mechanism
The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
The addition of a shunt trip enables remote control of tripping
Fingersafe terminals (meets IP20 standards)
Fingersafe terminals (meets IP20 standards)
AC network type
35 mm symmetrical DIN rail clippedPanel screwed with adaptor plate) fixing mode
Any position operating position
100 % 230/240 V AC 50/60 Hz IEC 60947-275 % 690 V AC 50/60 Hz IEC 60947-275 % 500 V AC 50/60 Hz IEC 60947-250 % 440 V AC 50/60 Hz IEC 60947-240 % 400/415 V AC 50/60 Hz IEC 60947-2 ics rated service short-circuit breaking capacity
17 to 23 A thermal protection adjustment range
327 A magnetic tripping current
690 V AC 50/60 Hz IEC 60947-2 ui rated insulation voltage
6 kV IEC 60947-2 uimp rated impulse withstand voltage