Banner Engineering SM2A912LVQD Valu-Beam® 912 Photoelectric Sensor, Rectangle Shape, 0.15 to 9 m Sensing, Visible Red Sensing Beam

Photoelectric Retroreflective Sensors
141340 MFG #: SM2A912LVQD
BANNER®
292.32000 / ea
  • Amperage Rating: 20 mA
  • Catalog Number: SM2A912LVQD
  • Connection Type: Quick-Disconnect
  • Country of Origin: USA
  • Enclosure Type: NEMA 1/2/3/3S/4/4X/12/13/IP66
  • Environmental Conditions: 90% at 50 deg C
  • Frequency Rating: 50/60 Hz
  • Gross Weight Per Pack: 1 lb
  • Light Source: LED
  • Operating Temperature: -20 to 70 °C
  • Sensing Method: Retro Reflective
  • Series: 912
  • Size: 36.6 mm L x 35.6 mm W x 77.5 mm H
  • Standards: CE Marked, CSA Certified, cULus Listed, RoHS Complaint
  • UNSPSC: 39121528
  • UPC 11: 66248826577
  • UPC 12: 66248826577
  • Voltage Rating: 24/250 VAC
  • Stock Status: NONSTOCK
  • Brand: BANNER®
  • Manufacturer: Banner Engineering Corp.
  • Output Type: Switch
  • Response Time: 4 ms
  • Sensing Beam: Red Laser
  • Sensing Range: 0.15 to 9 m
  • Shape: Rectangular
Banner Engineering Valu-Beam® Photoelectric Sensor, Series: 912, Rectangle, Retro Reflective Sensing Method, 0.15 to 9 m Sensing Range, Visible Red Sensing Beam, 4 ms Response, Switch Output, 24/250 VAC, 20 mA, 50/60 Hz, Quick-Disconnect, LED Light Source, 36.6 mm L x 35.6 mm W x 77.5 mm H, NEMA 1/2/3/3S/4/4X/12/13/IP66, -20 to 70 deg C Operating, Environmental Conditions: 90 Percent at 50 deg C
QTY
  • Features
Protected against transient voltages and false pulse on power-up; Stainless steel hardware; 912 Series ac sensors can be destroyed from overload conditions; Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state voltage of the sensor will interfere with proper operation of the load; The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts; Potentiometer located at rear of sensor
Less than or equal to 5 V RMS at 750 mA load and less than or equal to 10 V RMS at 15 mA load on-state voltage drop
Protected against transient voltages and false pulse on power-up
Stainless steel hardware
912 Series ac sensors can be destroyed from overload conditions
Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state voltage of the sensor will interfere with proper operation of the load
The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts
Potentiometer located at rear of sensor
912 series non-polarized retroreflective mode photoelectric sensor
Less than 1.7 mA off-state output leakage
4 ms on/off response time
650 nm visible red LED sensing beam
Acrylic lens, 90 percent at 50 deg C (non-condensing) relative humidity
3-pin mini-style quick disconnect connection
Reinforced thermoplastic polyester enclosure
Light/dark operate
SPST SCR solid-state 2-wire output, 10 mA minimum load current, 750 mA to 50 deg C, 500 mA to 70 deg C maximum steady-state load capability, 4 A for 1 Sec (non-repetitive) inrush capability, less than or equal to 5 V RMS at 750 mA load and less than or equal to 10 V RMS at 15 mA load on-state voltage drop