Banner Engineering SM2A912LVAGQD Valu-Beam® 912 Photoelectric Sensor, Rectangle Shape, 0.3 to 4.5 m Sensing, Visible Red Sensing Beam
Photoelectric Retroreflective Sensors
139556
MFG #: SM2A912LVAGQD
BANNER®
308.25000
/ ea
- Catalog Number: SM2A912LVAGQD
- Connection: 3-Pin Mini-Style Quick Disconnect
- Country of Origin: USA
- Enclosure: IEC IP66 NEMA 1, 2, 3, 3S, 4, 4X, 12 And 13 Reinforced Thermoplastic Polyester
- Environmental Conditions: 90 PCT At 50 ° C Relative Humidity
- Gross Weight Per Pack: 1 lb
- Leakage Current: Off-State Output: Less Than 1.7 MILAMP
- Lens: Acrylic
- Operating Temperature: -20 To 70
- Size: 36.6 MM Length X 35.6 MM Width X 77.5 MM Height
- Standards: CE Marked, CSA Certified, cULus Listed, RoHS Complaint
- Type: 912 Series Polarized Retroreflective Mode Photoelectric Sensor
- UNSPSC: 39121528
- UPC 11: 66248826653
- UPC 12: 66248826653
- Voltage Rating: 24 - 250 V
- Stock Status: NONSTOCK
- Brand: BANNER®
- Manufacturer: Banner Engineering Corp.
- Response Time: 4
- Sensing Beam: 650 NMTR Visible Red
- Sensing Range: 0.3 - 4.5
Banner Engineering Valu-Beam® Photoelectric Sensor, Series: 912, Rectangle, Retro Reflective Sensing Method, 0.3 to 4.5 m Sensing Range, Visible Red Sensing Beam, 4 ms Response, Switch Output, 24/250 VAC, 20 mA, 50/60 Hz, Quick-Disconnect, LED Light Source, 36.6 mm L x 35.6 mm W x 77.5 mm H, NEMA 1/2/3/3S/4/4X/12/13/IP66, -20 to 70 deg C Operating, Environmental Conditions: 90 Percent at 50 deg C
- Features
Protected against transient voltages and false pulse on power-up; Stainless steel hardware; 912 Series ac sensors can be destroyed from overload conditions; Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state voltage of the sensor will interfere with proper operation of the load; The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts; Potentiometer located at rear of sensor |
Less than or equal to 5 V RMS at 750 mA load and less than or equal to 10 V RMS at 15 mA load on-state voltage drop |
Protected against transient voltages and false pulse on power-up |
Stainless steel hardware |
912 Series ac sensors can be destroyed from overload conditions |
Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state voltage of the sensor will interfere with proper operation of the load |
The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts |
Potentiometer located at rear of sensor |
912 series polarized retroreflective mode photoelectric sensor |
Less than 1.7 mA off-state output leakage |
4 ms on/off response time |
650 nm visible red LED sensing beam |
Acrylic lens, 90 percent at 50 deg C (non-condensing) relative humidity |
3-pin mini-style quick disconnect connection |
Reinforced thermoplastic polyester enclosure |
Light/dark operate |
SPST SCR solid-state 2-wire output, 10 mA minimum load current, 750 mA to 50 deg C, 500 mA to 70 deg C maximum steady-state load capability, 4 A for 1 Sec (non-repetitive) inrush capability |