Banner Engineering SM2A912DQD Valu-Beam® 912 Photoelectric Sensor, Rectangular Shape, 760 mm Sensing, Infrared Sensing Beam
Photoelectric Proximity Sensors
147278
MFG #: SM2A912DQD
BANNER®
292.32000
/ ea
- Amperage Rating: 20 mA
- Catalog Number: SM2A912DQD
- Connection Type: Quick-Disconnect
- Country of Origin: USA
- Enclosure Type: NEMA 1/2/3/3S/4/4X/12/13/IP66
- Environmental Conditions: 90% at 50 deg C
- Frequency Rating: 50/60 Hz
- Gross Weight Per Pack: 1 lb
- Light Source: LED
- Operating Temperature: -20 to 70 °C
- Sensing Method: Diffuse
- Series: 912
- Size: 36.6 mm L x 35.6 mm W x 77.5 mm H
- Standards: CE Marked, cCSAus Certified, cULus Listed , RoHS Complaint
- UNSPSC: 39121528
- UPC 11: 66248826570
- UPC 12: 66248826570
- Voltage Rating: 24/250 VAC
- Stock Status: NONSTOCK
- Brand: BANNER®
- Manufacturer: Banner Engineering Corp.
- Output Type: Switch
- Response Time: 4 ms
- Sensing Beam: Infrared
- Sensing Range: 760 mm
- Shape: Rectangular
Banner Engineering Valu-Beam® Photoelectric Sensor, Series: 912, Rectangular, Diffuse Sensing Method, 760 mm Sensing Range, Infrared Sensing Beam, 4 ms Response, Switch Output, 24/250 VAC, 20 mA, 50/60 Hz, Quick-Disconnect, LED Light Source, 36.6 mm L x 35.6 mm W x 77.5 mm H, NEMA 1/2/3/3S/4/4X/12/13/IP66, -20 to 70 deg C Operating, Environmental Conditions: 90% at 50 deg C
- Features
Protected against transient voltages and false pulse on power-up; Stainless steel hardware; 912 Series ac sensors can be destroyed from overload conditions; Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state voltage of the sensor will interfere with proper operation of the load; The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts; Potentiometer located at rear of sensor |
Protected against transient voltages and false pulse on power-up |
Stainless steel hardware |
912 series ac sensors can be destroyed from overload conditions |
Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state voltage of the sensor will interfere with proper operation of the load |
The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts |
Potentiometer located at rear of sensor |
10 mA minimum load current, 750 mA to 50 deg C, 500 mA to 70 deg C maximum steady-state load capability, 4 A for 1 sec (non-repetitive) inrush capability |
Less than or equal to 5 Vrms at 750 mA load and less than or equal to 10 Vrms at 15 mA load on-state voltage drop |
SPST SCR solid state 2-wire switch |
912 series diffuse mode photoelectric sensor |
Less than 1.7 mA off-state output leakage |
4 ms on/off response time |
880 nm infrared LED sensing beam |
Acrylic lens, 90 percent at 50 deg C (non-condensing) relative humidity |
3-pin mini-style quick disconnect connection |
Reinforced thermoplastic polyester enclosure |
Light/dark operate, solid-state AC switch output |
18 mm barrel diameter |