Telemecanique XCSE731221S47, 220 to 240 V, 3 Poles
Interlock Switches - Trap Key
PDW~12913894
MFG #: XCSE731221S47
Telemecanique Sensors
609.00000
/ ea
- Action: SLOW-BREAK, BREAK BEFORE MAKE
- Alternate Catalog Number: XCSE731221S47
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: XCSE731221S47
- Connection: Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
- Contact Configuration: 2 NC + 1 NO
- Country of Origin: FR
- Currency: USD
- EU RoHS Indicator: Y
- Gross Volume Per Pack: 161.18
- Gross Volume per Pack Metric: 2641.26
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 2.9770 lb
- Gross Weight per Pack Metric: 1.35
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536509055
- Height: 4.29 in
- Height [Metric]: 11.0000 cm
- Item Group: 22411
- Length: 7.22 in
- Length [Metric]: 18.5000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=859252&lang=en-us
- Returnable: N
- Sub Brand: XCSE
- Type: SAFETY SWITCH
- UNSPSC: 39122213
- Width: 4.29 in
- Width [Metric]: 11.0000 cm
- Brand: Telemecanique Sensors
- Manufacturer: Telemecanique Sensors
- Voltage Rating: 24 V - 20...10 %
- Number Of Poles: 3
- Features
for guard open/guard closed and locked 2 LEDs (green or orange);Locking on de-energisation and unlocking on energisation of solenoid;Overvoltage protection signalling circuit |
Rectangular design |
2 entries tapped for M20 x 1.5 cable entry |
Locking on de-energisation and unlocking on energisation of solenoid electromagnet interlocking |
24 V - 20 to 10 % us solenoid rated supply voltage |
0.28 to 0.51 in 7 to 13 mm cable outer diameter |
With interlocking, locking by solenoid locking options description |
24/48 V 20 to 52 V signalling circuit voltage |
With NC contact positive opening |
1 load factor |
7 mA signalling circuit consumption |
7 mA signalling circuit consumption |
1000000 cycles mechanical durability |
03 ft/s 01 m/s minimum actuation speed |
1.64 ft/s 0.5 m/s maximum actuation speed |
50 VEN/IEC 60947-1 signalling circuit ui rated insulation voltage |
6 kV EN/IEC 60947-5-1 uimp rated impulse withstand voltage |
Overvoltage protection signalling circuit protection type |
10 A cartridge fuse gG gl short-circuit protection |
2000 N actuator forcible withdrawal rtc |
20 N minimum actuator force for extraction |