Telemecanique XCMD3902L2 Standard format Standard format, 300 V, Roller Plunger Actuator, 2NC+1NO Contact, 3 Poles
Plunger Actuated Limit Switches
PDW~12318305
MFG #: XCMD3902L2
Telemecanique Sensors
68.20000
/ ea
- Action: Lateral approach, 2 directions;Snap action;By 30?° cam
- Alternate Catalog Number: XCMD3902L2
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: XCMD3902L2
- Connection: REMOVABLE CABLE CONNECTOR
- Country of Origin: ID
- Currency: USD
- EU RoHS Indicator: Y
- Gross Weight Per Pack: 0.4580 lb
- Gross Weight per Pack Metric: 208.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 8536509055
- Height: 0.78 in
- Height [Metric]: 2.0000 cm
- Item Group: 22413
- Length: 4.68 in
- Length [Metric]: 12.0000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=857886&lang=en-us
- Mounting: BY THE BODY
- Returnable: N
- Size: 0.63 in
- Sub Brand: XCMD
- Substitute Product Catalog Number: XCMZ06
- Type: Limit switch
- UNSPSC: 39122213
- Warranty Description: Contractual Warranty:18 months
- Width: 4.68 in
- Width [Metric]: 12.0000 cm
- Brand: Telemecanique Sensors
- Manufacturer: Telemecanique Sensors
- Actuator: Spring return roller plunger metal
- Contact Configuration: 2 NC + 1 NO
- Number Of Poles: 3
Telemecanique XCMD3902L2, Standard format, Series: Standard format, 300 V, 2NC+1NO Contact Configuration, 3 Pole, Linear Action, Roller Plunger Actuator, Removable Cable Connector Connection, IP66/IP67/IP68 Enclosure, Fixed Mounting, 10000000 Cycles Operating Cycles, -13 to 158 deg F Operating, Metal, TC, Environmental Conditions: -40 to 158 deg F Storage Temperature, -13 to 158 deg F Operating Temperature
- Features
Fixed body type |
Zamak body material |
Zamak head material |
By the body fixing mode |
Lateral approach, 2 directions type of approach |
By 30 deg cam switch actuation |
6.56 ft 2 m cable length |
7 x 0.5 mm2 cable composition |
PvR wire insulation material |
With positive opening |
With positive opening |
35 N positive opening minimum force |
7 N minimum force for tripping |
01 m/min minimum actuation speed |
1.64 ft/s 0.5 m/s maximum actuation speed |
300 V 3 UL 508400 V 3 IEC 60947-5-1300 V 3 CSA C22.2 No 14 ui rated insulation voltage |
25 mOhm IEC 60255-7 category 3 maximum resistance across terminals |
4 kV IEC 606644 kV IEC 60947-1 uimp rated impulse withstand voltage |
6 A cartridge fuse gG short-circuit protection |