Telemecanique XCKT2510G1103 Standard format Standard format, 300 V, Plunger Actuator, 1NC + 1NO Contact, 2 Poles

Plunger Actuated Limit Switches
PDW~12432465 MFG #: XCKT2510G1103
Telemecanique Sensors
84.00000 / ea
  • Action: Slow-break, break before make;On end
  • Alternate Catalog Number: XCKT2510G1103
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: XCKT2510G1103
  • Connection: Screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
  • Country of Origin: FR
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 15.12
  • Gross Volume per Pack Metric: 247.77
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.1890 lb
  • Gross Weight per Pack Metric: 86.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536509055
  • Height: 1.36 in
  • Height [Metric]: 3.5000 cm
  • Item Group: 22418
  • Length: 3.90 in
  • Length [Metric]: 10.0000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=857508&lang=en-us
  • Mounting: BY THE BODY
  • Returnable: N
  • Sub Brand: XCKT
  • Type: Limit switch
  • UNSPSC: 39122213
  • Width: 2.50 in
  • Width [Metric]: 6.4000 cm
  • Brand: Telemecanique Sensors
  • Manufacturer: Telemecanique Sensors
  • Actuator: Spring return plunger metal
  • Contact Configuration: 1 NC + 1 NO
  • Number Of Poles: 2
Telemecanique XCKT2510G1103, Standard format, Series: Standard format, 300 V, 1NC + 1NO Contact Configuration, 2 Pole, Linear Action, Plunger Actuator, Screw Terminals Connection, IP66/IP67 Enclosure, 15000000 Cycles Operating Cycles, -13 to 158 deg F Operating, Plastic, TC, Environmental Conditions: -40 to 158 deg F Storage Temperature, -13 to 158 deg F Operating Temperature
QTY
  • Features
Fixed body type
Plastic body material
Zamak head material
By the body fixing mode
Vertical approach, 1 direction type of approach
On end switch actuation
2 entries tapped for Pg 11 cable gland cable entry
Zb contacts insulation form
With positive opening
15 N minimum force for tripping
15 N minimum force for tripping
6 m/min minimum actuation speed
1.64 ft/s 0.5 m/s maximum actuation speed
300 VUL 508500 V 3 IEC 60947-1300 VCSA C22.2 No 14 ui rated insulation voltage
25 MOhm IEC 60255-7 category 3 maximum resistance across terminals
6 kV IEC 606646 kV IEC 60947-1 uimp rated impulse withstand voltage
10 A cartridge fuse gG short-circuit protection
15000000 cycles mechanical durability
Class II conforming to IEC 61140Class II NF C 20-030 electrical shock protection class