Bussmann® NOS-60 Non-Indicating Non-Rejection Non-Renewable Fast Acting Fuse, 600 VAC, 60 A, 50 kA at 600 VAC, K5
One-Time Fuses
4940
MFG #: NOS-60
Bussmann
88.33000
/ ea
- Alternate Catalog Number: NOS-60
- Application: Ind Facilities & Factories - Facility: Safety and Security Systems
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: NOS-60
- Connection: Ferrule end x ferrule end
- Country of Origin: MX
- Currency: USD
- EU RoHS Indicator: C
- Gross Weight Per Pack: 0.2500 lb
- Gross Weight per Pack Metric: 0.14
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536100040
- Height: 5.50 in
- Height [Metric]: 13.9700 cm
- Length: 1.60 in
- Length [Metric]: 4.0640 cm
- Size: 1.050 In Diameter X 5.50 In Length
- Standard: CE Marked
- Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL Listed
- Sub Brand: Bussmann Series
- Type: Fuse
- UNSPSC: 39121605
- UPC 11: 05171231060
- UPC 12: 051712310604
- Width: 1.60 in
- Width [Metric]: 4.0640 cm
- Stock Status: NONSTOCK
- Brand: Bussmann
- Manufacturer: Eaton
- Amperage Rating: 60 A
- Class: Class K5Class H
- Interrupt Rating: 50 kAIC at 600 Vac kA
- Voltage Rating: 600 V
- Brochure URL - COBUSSE01827_25.pdf(Brochure URL)
- Catalog URL - IDW_DOCUMENT_1a75486c91eac72d6d9341aa0b76dca0d20879f49ebc32559f9fec4e6045f955.pdf(Catalog URL)
- Spec Sheet 2 URL - Bussmann_NON_20_Specification_Sheet_2.pdf(Spec Sheet 2 URL)
- Spec Sheet 1 URL - Bussmann_NON_20_Specification_Sheet_1.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 10973_V2BQLPJS4KNUZ9HI.pdf(Spec Sheet URL)
- http://www.bussmann.com(Seller Home Page URL)
- Spec Sheet URL - NOS-60(Spec Sheet URL)
- Tech Drawing URL - Bus_Ele_DS_1030_NON_NOS.pdf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/YMvqUyoETXk(Video)
- Spec Sheet URL - skuPage.NOS-60.pdf(Spec Sheet URL)
- Tech Bulletin URL - datasheet.php?model=FNQ-30&locale=en_GB(Tech Bulletin URL)
- Applications
- Features
Ind Facilities & Factories - Facility: Safety and Security Systems |
Non current limiting |
Protect lighting, Heating and other circuits not subject to temporary surges and where available short circuit currents are relatively low |
NON one time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur |
Use Bussmann series advanced protection FUSETRON™ FRN-R or ultimate protection Low-Peak™ LPN-RK dual-element, time delay fuses |
For general purpose circuits, size at amp rating of circuit |
For motor circuits, size at 300% to 400% according to the NEC® motor ampacity tables 430.247 to 430.250, per 430.6(A)(1) |
50 kA at 250 VAC RMS sym |