Bussmann® NON-30 Non-Indicating Non-Rejection Non-Renewable Fast Acting Fuse, 250 VAC/125 VDC, 30 A, K5
One-Time Fuses
4708
MFG #: NON-30
Bussmann
10.45000
/ ea
- Alternate Catalog Number: NON-30
- Application: Ind Facilities & Factories - Facility: Safety and Security Systems
- ARRA Compliant: C
- Body Size: 0.56 in Dia x 2 in L
- Buy American Compliant: C
- Catalog Number: NON-30
- Connection: Ferrule end x ferrule end
- Country of Origin: MX
- Currency: USD
- Element: Single
- EU RoHS Indicator: C
- Gross Weight Per Pack: 0.0550 lb
- Gross Weight per Pack Metric: 0.02
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536100040
- Height: 0.56 in
- Height [Metric]: 1.4224 cm
- Length: 2.00 in
- Length [Metric]: 5.0800 cm
- Material: Melamine
- Mounting Type: Holder
- Series: NON
- Size: 0.56 In Diameter X 2.00 In Length
- Standard: CE Marked
- Standards: ARRA CompliantRoHS CompliantBuy American Act Compliant
- Sub Brand: Bussmann Series
- Terminal Type: Ferrule
- Type: Fuse
- UNSPSC: 39121605
- UPC 11: 05171210159
- UPC 12: 051712101592
- Width: 0.56 in
- Width [Metric]: 1.4224 cm
- Stock Status: NORMALLY STOCKED
- Brand: Bussmann
- Manufacturer: Eaton
- Amperage Rating: 30 A
- Class: H
- Interrupt Rating: 50 kAIC at 125 Vdc50 kAIC at 250 Vac kA
- Voltage Rating: 250/125 VAC//VDC
- Brochure URL - COBUSSE01827_25.pdf(Brochure URL)
- Catalog URL - IDW_DOCUMENT_1a75486c91eac72d6d9341aa0b76dca0d20879f49ebc32559f9fec4e6045f955.pdf(Catalog URL)
- Spec Sheet URL - 10973_6VCGXWZQIB37JR2O.pdf(Spec Sheet URL)
- Spec Sheet 2 URL - Bussmann_NON_20_Specification_Sheet_2.pdf(Spec Sheet 2 URL)
- Spec Sheet URL - NON-30(Spec Sheet URL)
- http://www.bussmann.com(Seller Home Page URL)
- Tech Bulletin URL - datasheet.php?model=FNQ-30&locale=en_GB(Tech Bulletin URL)
- Video - https://www.youtube.com/embed/YMvqUyoETXk(Video)
- Spec Sheet URL - skuPage.NON-30.pdf(Spec Sheet URL)
- Tech Drawing URL - Bus_Ele_DS_1030_NON_NOS.pdf(Tech Drawing URL)
- Applications
- Features
Ind Facilities & Factories - Facility: Safety and Security Systems |
Non current limiting |
Protect lighting, Heating and other circuits not subject to temporary surges and where available short circuit currents are relatively low |
NON one time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur |
Use Bussmann series advanced protection FUSETRON™ FRN-R or ultimate protection Low-Peak™ LPN-RK dual-element, time delay fuses |
For general purpose circuits, size at amp rating of circuit |
For motor circuits, size at 300% to 400% according to the NEC® motor ampacity tables 430.247 to 430.250, per 430.6(A)(1) |
50 kA at 250 VAC RMS sym |